    New hot water and heating boiler

    If you have 6 bedrooms over 3 floors then i wouldn't be using a system boiler, or if i was i would possibly using a low loss header as the resistance across the giannoni exchanger is very restrictive. That will also be the problem with your current boiler although the resistance across the...
  2. S

    Solar Panels

    Inverter is 5kw due to combined battery plus panels. They then allow you take up to 5kw from a combination of batteries and panels eg when you boil The kettle etc. your demand will Then be satisfied without taking from the grid.
  3. S

    Honeywell T3R thermostat keeps increasing the temp.

    take the batteries out and bend the metal spring tab out so it has a tighter fitting. if this is loose it can cause various issues, but the most common is the heating coming on when it shouldn't be.
  4. S

    Pre Heated water into Oil Combi

    if you have a free supply of 7kw i would get an air source fitted tomorrow? you can get hybrid but who cares if you can have that much electric for free. you could have 2 units fitted and unless you live in a mansion all your heating and hot water should then be free
  5. S

    using washers in oil line coupling

    What age burner is this? I think the fault may not be with the pump and is with the control cox or the photocell. If the photocell fails it causes the motor to run continuously and in this causes the oil pump to overheat, the oil pump uses the oil flowing through it to cool it. Problem being...
  6. S

    using washers in oil line coupling

    Start at the basics. clean or renew filter at the tank. replace filter at filter bowl with a fine paper filter 10micron max i assume the new oil pump cam with a new solenoid. if not replace solenoid ( when they start to fail they fail at 30-40mins and eventually fail after 5 mins down to...
  7. S

    Grant Combi 90 MKII Issue - Any help or advice greatly appreciated!

    i'm guessing it still has a G5 but he is referring to the red light on the control panel. pump solenoids rarely fail on riello's so i would be looking at fuel starvation. I would check the filter at the tank is clean first.
  8. S

    BG330+ Boiler Replacement

    when you say leaking from the pipe. do you mean the grey/white flexible pipe beneath the boiler? not uncommon for these to leak where they are pushed onto plastic condensate pipe. Not a great fit sometimes. Just a cable tie will solve the leak most times. If it leaking from within the boiler...
  9. S

    BG330+ Boiler Replacement

    can't get the seals!! really. everything is still available spares wise for this boiler
  10. S

    Worcester Bosch Greenstar 8000 Life problems....Or are they???

    the gas valve failure will cause loss of both heating and hot water so it is not the cause of your issue
  11. S

    Worcester Bosch Greenstar 8000 Life problems....Or are they???

    I install worcester boilers, and they contacted me yesterday to say that one of my 8000 installs needed it's gas valve changing as it was one within the affected range.
  12. S

    Worcester Bosch Greenstar 8000 Life problems....Or are they???

    There is a problem with the gas valve on some of the 8000 boilers . All owners will be contacted over the next 2 months to replace those affected . Not sure what is the issue with the gas valve. I would get Worcester back if you are unhappy but make sure explain the problem so the engineer solves it
  13. S

    New motor noise

    not in my experience. especially if water contamination
  14. S

    New motor noise

    probably also shot the pump bearings.
  15. S

    Heatslave 12/14 lockout

    https://www.hwos.co.uk/tradestore/oil/burner-spares/motors/bentone-1/bentone-70w-direct-drive-motor-bentone-b9-inter-b9-m02-1-70-03-b2402
  16. S

    Heatslave 12/14 lockout

    your multimeter doesn't have the facility to check a capacitor
  17. S

    Pre paid gas not working after running out

    think OP is confused. he only needs to press reset on the boiler ( top left button). He thinks the problem is still with the gas meter!
  18. S

    Wallstar Boiler working with panel off?

    oil solenoid coil is the most common fault for this, But second most common fault is the ignition unit. it is recommended on the benetone boilers that a combination of these components are changed at certain intervals.
  19. S

    Hot water problems

    if it only affected the shower then the fault is with the shower. But when these older megaflow cylinders start to fail the internal baffle breaks apart and can then block the hot feed on showers etc. This cylinder is at least 20 years old and replacing it maybe the right thing to do. But i...
  20. S

    Sealant Issues

    cut it out and use dow corning