Search results

  1. G

    Double under oven and hob

    910mm normally. This does not help as the double oven needs to sit flush with the bottom of the units not the floor.
  2. G

    Double under oven and hob

    Can anyone help with a problem which i cannot see a way out of. I have units that are 720mm tall. The double under oven is 717mm. The back of the oven is 711mm - 6mm lower than the front of the oven. This seems to be pretty standard. I have a granite worktop which is 30 mm thick. All...
  3. G

    fitting 900 hob onto units

    Ok let me try a different question. I don't want to buy expensive items and find they don't fit. My problem as i see it. I have units that are 720mm tall. The double under oven is 717mm. The back of the oven is 711mm - 6mm lower than the front of the oven. This seems to be pretty standard...
  4. G

    fitting 900 hob onto units

    I have ordered a kitchen and intend to fit myself. I used to do bathrooms so quite handy but i cant get my head around how i will fit the 900mm hob i have ordered. The units sit each side of the double under oven which is 600mm. You normally have to have a 50 mm gap for heat, so the only way...
  5. G

    New induction hob

    Back to business for a second. Has anyone heard of not putting a induction hob above a double oven? I found this on one website: Please note: Induction hobs cannot be placed above built-under double ovens All warranties must be registered with the manufacturer Manufacturer's warranty...
  6. G

    New induction hob

    Thanks guys. I have spoken to my sparky who said without looking at it he thinks that the two sets of cables can be linked together and run off a single 10mm cable. Does this sound feasable or is there any logical reason why they should be seperated?
  7. G

    New induction hob

    De Dietrich 90cm Induction Hob with Continuum Zone Hob DTi749V. I have yet to take delivery but have found out that there are two cables from a review on amazon. Hope this helps!
  8. G

    New induction hob

    Please can someone tell me the size of cable required for my new hob. The hob comes with two cables to connect to two cooker points (each of 30 amps or one of 60amps). Total hob amps is 52. Can someone advise. Many thanks.
  9. G

    New roof including new roof timbers

    Guys. Thanks for the replys this gives me a bit of ammo to go back to the sellers with. Much appreciated.
  10. G

    New roof including new roof timbers

    Sorry to clarify. After reading other posts i dont think we have to remove all the old timber but repace tiles and re felt, plus get all of the old foam insulation off.
  11. G

    New roof including new roof timbers

    Guys . I am looking for an indication on cost fo a new roof on a house we are looking to buy. We have had a bit of a shock on the survey which has highlighted the need for the roof. The woodwork has apparantly been coated with spray type insulation to prolong the life of the roof surfaces...
  12. G

    Negative head pump.

    many thanks for your help
  13. G

    Negative head pump.

    Many thanks. i have been trying to find a low bar pump (1.5 ish) as only feeding hot tap. Any suggestions
  14. G

    Negative head pump.

    Can someone advise if the best solution for a friends loft conversion. Currently they have a single positive head pump to the basin in the loft. This does not work because there is no flow rate to get the pump started as the f&e tank is below the tap. Is the only solution a negative head...
  15. G

    megaflow - draining central heating

    similar to a combi then. Thanks
  16. G

    megaflow - draining central heating

    Please can someone adivse how to drain the central heating on a megaflow. Do you just drain as per a normal open vented system. If you drain like normal how do you refil. Please advise Thanks
  17. G

    Electric Underfloor heating for tiled floor.

    follow up question. Am i able to use marmox board straight onto 22mm chipboard flooring using flexi floor cement?
  18. G

    New radiator pipework.

    please clarify. I thought a combi had the valve within the boiler and cylinder/external pump and 2/3port valve would be gone
  19. G

    New radiator pipework.

    was thinking of putting a combi in sometime in the future and i like to understand how the systems work. There is a valve in there at the moment.
Back
Top