    Draining radiator -rad pipe to close to wall

    This seems a lot of fuss for something very simple. Close both valves, open vent to check they are both shut. As said, hold valve with stilsons and undo nut, gently pull pipe away and substitute valve for 1/2BSP stop end. Move to other side and repeat. The water will only exit rad as fast as air...
  2. K

    Repressurising sealed CH system.

    I can't think of how that can be done unless you have a fairly recent Logic, in which case there's a "vent system" function in the menu.
  3. K

    Grohe Concealed cistern fault

    Sorry, typo on my part, I meant don't use Grohe parts.
  4. K

    Grohe Concealed cistern fault

    I would replace the components, but use Grohe ones. Similar components are readily available for a fraction of that price.
  5. K

    Cleaning plate heat exchanger issues

    Normally only primary (heating) side gets clogged. Brick acid is my go to solution.
  6. K

    Shower, rounded grub screw cant remove cover, replace shower?

    Drill grub screw out, then enlarge hole & rethread?
  7. K

    Any chance of removing snapped refill key from boiler?

    Assuming it's fully inserted, just leave it, you will use the the square white tap to refill boiler. Replacing the whole assembly is only a 10 min job.
  8. K

    Service engineer let the air out of expansion vessel?

    He's an idiot, do not let him near your boiler again. EV should have a charge of around 1 Bar
  9. K

    Hive system - Logic combi ESP1

    I think you will need the single channel Hive, as opposed to what you have. Why didn't installer change it, or advise you?
  10. K

    Ideal Boilers

    Both boilers are accessed from the front for maintenance, so you only need a few mm clearance at the side.
  11. K

    Faulty boiler thermostat

    Looks the correct head to me, you will need to line up the flats on the spindle (brass bit) with the flats in the actuator. Sometimes moving the actuator manually (plastic lever on the end) helps.
  12. K

    Boiler help/advice

    Because the mains pressure is higher than system pressure, a plate heat exchanger leaking internally would indeed cause the pressure to increase.
  13. K

    Hot water tank only getting to 46deg even with boiler on constant at 75deg??

    You can check the thermostat by watching the zone valve as you alter the stat, it should close when stat turned down (assuming cylinder is warm), and open when turned up. There's every chance it's been wired wrongly too.
  14. K

    Hot water tank only getting to 46deg even with boiler on constant at 75deg??

    Turn the cylinder stat right up and see what happens
  15. K

    DECENT FIXINGS TO HANG RADS

    You should be able to get a good fix into the blocks with conventional screw and plug, however, the Manu's of those brackets are stupid, in that they space the holes far too closely in the brackets, which means you run the risk of drilling first hole fine, but then the 2nd hole shaetters the...
  16. K

    Remove speedfit coupler - causing problems

    As above, rigid copper connections through wall/cavity
  17. K

    Logic+ c30 combi filing loop taps..?

    Both black taps should be in a vertical position
  18. K

    Condensate pipe weeping

    Did I mention a hose clip 25 pages ago? :ROFLMAO: