Search results

  1. W

    Potterton Profile 60e / Grundfoss Pump

    Hi sounds like you have a micro switch in your motorised valve still making contact, most likely the heating one. What make of valve/ valves do you have?.
  2. W

    Ideal classic FF250 and Lifestlye LP241

    Hi sounds more like an external problem rather than anything wrong with your boiler, try looking at external controls fro heating motorised valve,room thermostat etc.
  3. W

    Quote for heating system

    Hi guys thanks for your replies, the system required will be a 4 or 5 rad system with a Remeha Avanta 28 condensing boiler in a council flat which is ocupied, there is no system to be removed only an old multipoint water heater.
  4. W

    Manifold question

    Hi yes move one of the pipes to a left connection.
  5. W

    Quote for heating system

    Hi i'm looking for a quote for a full central heating system to a 2 bed flat in South london, anyone interested or rough price.
  6. W

    Manifold question

    Hi if you move the left hand pipe to one of the three top left hand blank connections i think you find it will work.
  7. W

    Heating wont turn off

    Hi what type of motorised valves do you have?. Could be one of your valves is stuck open which would keep micro switch closed and could give you the symptoms you describe.
  8. W

    Blocked Cold Feed?

    Hi when you have found and removed your blockage also remove any valves such as the gate valve you show from the feed and expansion pipe,as you should not have any isolation valves etc in either feed&expansion pipework or open vent pipework.
  9. W

    alpha240p

    Hi could be domestic hot water diaphragm, check if plunger comes out and works micro switch. Drop down front flap and it's the large round part to the left with micro switch attached.
  10. W

    70s Taps

    Hi do you mean Supa taps, the ones which had a shut off valve so you could change the washer without turning off the water supply?.
  11. W

    Minor work cert's

    What would No 6 be classed as then ?.
  12. W

    Minor work cert's

    1) New spur for boiler in kitchen 2) Replacement pump, m/valves, roomstat, cylinder stat, programmer etc. 3) New wiring to existing heating controls. 4) New wiring for new heating controls. 5) New lighting circuit from existing. 6) New lighting circuit from c unit. That type of works.
  13. W

    Minor work cert's

    Hi everyone i'm looking for advice on what work does and doesn't require a minor works cert.
  14. W

    Ocean Alpha 240P DHW valve leak

    Update Alpha 240p is a permanent pilot model, i look after approx 40 of these boilers on a yearly contract .
  15. W

    Ocean Alpha 240P DHW valve leak

    Domestic hot water section shown it that link won't help you, you only need to buy a replacement front section of the diverter valve these are quite easy to replace as i have said already.
  16. W

    Shower Pump with a life of its own!

    Were you running any other taps, flushing toilet etc? might have sensed some flow else where, could be just a pocket of air somewhere seeing as you have turned off water and drained to fit it, see if it happens again might be a one off.
  17. W

    Upgrading a primatic tank

    Hi you will need to change your primatic cylinder and fit a indirect cylinder, also you will need to install a feed and expansion tank to feed the heating. As your existing hot water must be gravity you would need to change this to pumped which would require control valves and thermostats etc...
  18. W

    Pls HELP Tiny black flies in my bathroom sink & bath YUK

    If you haven't got any storage tanks then you must have everything on the mains, in which case you won't need to clean so it probably will be something to do with wastes as suggested.
  19. W

    Pls HELP Tiny black flies in my bathroom sink & bath YUK

    You should look at your cold water storage cistern/tank in your loft, it could need cleaning out and sterialising, also it might not have the close fitted lid, screened overflow, screened vent and insulation that is required.
  20. W

    Ocean Alpha 240P DHW valve leak

    Hi if you turn off all valves under boiler ie flow,return & cold mains water in plus electrics and drain boiler. Remove front micro switch, undo both small pipes from top of diapragm housing, lossen both retaining screws at rear of diapragm housing the housing will come off and you will see the...
Back