  1. N

    Flourescent lights & circular saws

    Anyway, I did it properly & used high frequency fittings (thanks to the replys on this forum :D ). They were £20 dearer each, than the normal flourescents, but its quite a serious looking workshop & thats what he wanted.
  2. N

    NICEIC Domestic Installers

    Dunno about you lot but I got a conscience. I'm currently applying for my NIC DI & if I thought any of my work went up i smoke, I'd be pretty pi**ed off. I would do every job as if I was working on my own house. You cant apply for Approved Contractor until you've done at least 6 months of DI...
  3. N

    Flourescent lights & circular saws

    woooo that was a quick reply... :)
  4. N

    Flourescent lights & circular saws

    Fitting some fluorescent lights in a workshop tomorrow for a chipie. I thought I heard somewhere that if you have fluorescent lights on, when using, say, a circular saw, it looks like the blade isnt going round. Anyone else heard of this ?
  5. N

    Meter Tails

    Dont wanna hi-jack your post but I've got the same situation. I've changed my CU for an assessment & there is a 100A main fuse with 16mm tails. :shock:
  6. N

    megger wandering lead

    This is the seller I got it off - sdm004. Have to do a search & e-mail him.
  7. N

    Megger MFT1552 question

    The manual came on a disk which I printed out. I've done a complete test on my house & all the results were within the limits. Just wanted to double check I was doing the 'LOOP' bit right, that was all.
  8. N

    megger wandering lead

    I got mine off e-bay, bout 15 quid
  9. N

    Megger MFT1552 question

    I just want to clarify the 'Loop' settings on the MFT1552 I have. Single phase - If I was checking Zs on a RCD or non-RCD protected circuit I would put it on 'NO TRIP', or if I was checking Ze I could put it on 'NO TRIP'. (using red, black & green wires for testing) Single phase & 3 phase...
  10. N

    Soldering Techniques

    You can buy it from RS Components. Heres a link (Dont know how to make the words 'RS Components' as a link)...
  11. N

    Working out Maximum Demand

    Thanks for confirming that Adam_151. I originally put down 52A & then changed it cause I thought someone might say it was 51.76. :? oh & I'm not blonde :wink:
  12. N

    Working out Maximum Demand

    Right then, I'm filling out a Domestic Electrical Installation Cert & its asked for Maximum Demand. It says nothing about using diversity on the cert but in my Inspection, testing & cert book it says you can make an allowance for diversity. The circuits in my CU are Final ring for sockets...
  13. N

    Working out MD for lights

    When working out Maximum demand for lighting circuit, I've got 4 50w mains halogen spotlights. Is this classed as 200w? If I got 4 20w LV halogen spots, is this classed as 80w. Cheers.
  14. N

    CU testing questions

    I thought I had finished with this post & then I was looking through the 'Inspection, testing & Certification' book & this is what is says about recording distribution circuits. "Every circuit, including distribution circuits (submains) must be recorded. The first line of the schedule of...
  15. N

    CU testing questions

    Thanks comms
  16. N

    CU testing questions

    A couple of questions about testing a CU replacement in the house 1. Ive got a supply for my garage on the RCD side in the house & then a non-rcd CU in the garage. Not sure if I have to record any test results regarding the garage supply on the EIC when testing the house CU replacement. 2...
  17. N

    Insulation resistance on a transformer

    ok thanks.
  18. N

    Insulation resistance on a transformer

    err........ yeah :oops: dont know I'll look tomorrow. yep. It doesnt trip everytime, its a bit intermittant.