    heatrae megaflo cylinders

    guys, could you give me the link to a site where i can peruse manufacturers instructions for these, cheers
  2. M

    flavel misermatic fire

    thanks guys, thats a relief, no pun intended.
  3. M

    flavel misermatic fire

    customer had inherited this fire, prob only 2 years old, and i went to service it. No man instructions available so serviced to british standards. What i did notice was that there was no air relief holes in the closure plate, (seemed to be the correct plate for fire) and it toiled to pass both...
  4. M

    Vokera Maxin 28e Boiler

    Sounds to me like the venturis (where air tubes are connected to flue) could be blocked. Power off at spur then take off covers (shouldnt be doing this if you re not RGI but as you have already done this) and remove clamp at fan /flue connection. Take off both air pipes, remember where they...
  5. M

    Vokera Maxin 28e Boiler

    sounds like expansion vessel requires to be recharged slightly but it is not what is making your system faulty. Is the boiler actually locking out, (led illuminating) or is it just idle. Is it when it reaches primary temp (on gauge) or does this happen at any given time and is it more likely...
  6. M

    Vokera Maxin 28e Boiler

    what is the pressure when cold, does it drop low
  7. M

    Vokera Maxin 28e Boiler

    sounds like its overheating, what is the system pressure at
  8. M

    Understanding my WB Greenstar 25Si ?

    yep , sorry did get confused, was tryin to think bout several things at once , cant multitask :oops:
  9. M

    Understanding my WB Greenstar 25Si ?

    just press it the once, dont have to keep messin with it. U cant prog the hot water as it is a combi mate, it is a generic prog ie if you wanted to hook it up to a cylinder to make it a system boiler
  10. M

    Could this be carbon monoxide?

    yes it could be, ive shut a few of these down for cracks inside cylindrical heat ex/combustion area, as said ,switch off and get someone round mate.
  11. M

    what would you do if

    ok mate, will give it a bash
  12. M

    what would you do if

    In a private car park, a car pulls in space next to you, owner gets out and the door is blown/carelessly opened and damages your door. Other driver doesnt want to know, no witnesses, cctv etc and immediately leaves scene. Got car reg and description of other driver, is it worth pursuing this...
  13. M

    central heating wont turn off!

    motorised head on divertor valve
  14. M

    Problem with Vokera Compact boiler

    yes it can, before u start push schraeder valveto see if any air coming out, if only water coming outexp vessel gubbed and will need replaced. Remember a faulty exp vessel would cause your pressure to rise to around 3 bar with ch on
  15. M

    Problem with Vokera Compact boiler

    does your pressure rise a great deal when the ch is on, this would point towards your expansion vessel. however if this is not happening it could probably be your pressure release valve passing water, check outside on blow off pipe coming through wall
  16. M

    Photos Vaillant Installation your views

    it is allowable for the copper gas pipe to be open to atmosphere as long as it is not near a corrosive area, near the seaside etc. Boiler also far too close too combustible materials, if no signs of scorching to cupboards or boiler this is usually regarded as not to current standards. Job...
  17. M

    recharging an expansion vessel

    i use a cheap foot pump for car tyres out of halfords, done me well
  18. M

    sime friendly format 80e div assy help

    fitting one of these next week, never worked much on these boilers and it looks like a nightmare. Does the gas valve need to come off to get to this and if anybody has changed one before let me know any handy hints /tips. A link to the instructions would also prove helpful, cheers.
  19. M

    Boiler Losing Pressure

    is pressure rising sharply when heating is on, if so its the expansion vessel, plenty links on this site how to fix. If not ,to determine properly where leak is shut off flow and return to boiler for a day or so and monitor pressure, if no loss during this time leak is on pipework. Only problem...