  1. B

    Worcester 28i RSF Problem

    What the gc number for the boiler? Sometimes the fitler just sits on the return valve and doesnt have a part number as its part of the valve.
  2. B

    Leaking radiator advice please

    Never had to use anything else but ptfe and never will.
  3. B

    Worcester 28i RSF Problem

    Vid doesnt work for me? Sound like from what you say it is having a problem getting rid of the heat when its running the heating, so flow filter could be one to check so to if there is dirt in there.
  4. B

    have bled radiators: still only hot @ bottom but cold @ top

    ^^^ Agree If you dont get air out, the air point can be blocked with dirt (which as you state you have a 3 storey house, you mean it a pretty new build, so dirt will be a factor). You must get water out of the top to ensure the radiator is full of water.
  5. B

    Potterton Suprima 60L

    Has it still got is 1st edition pcb on? (the pcb status light will only have 2 colours red/green) If so 99% of the time its the pcb imo when the gas valve fails it normally wont reset, a gas safe engineer can check the resistances on the gas valve to check if they are in range. I would...
  6. B

    Potterton Suprima 60L

    Yeah you need to replace the PCB comes with a wiring kit also.# Common fault, starts out needing a rest every now and then, to every 2 mins, to wont reset.
  7. B

    Getting the right size wood burner.

    Thanks for the reply. I am gas safe engineer so i know the chimney is ok. I am also doing an extension, so bc will be coming out to check that work, so i was going to fit the wood stove at the same time so i hope they will sign it off at the same time? Thats great i might go for the...
  8. B

    Rad keeps going cold

    You say you had the system flushed when the boiler was installed, doesn't mean blockages wont form after a while. You need to get the system fully balanced, simple.
  9. B

    Getting the right size wood burner.

    Thanks for that info mate. I have used online calculators and they have come out at 7kw. The room is 9mtrs long, 6mtrs wide for 6mtrs of the length then 3mtrs wide for the other 3 mtrs on length. About 45 sq mtrs room is standard 2.4 mtrs high. 108m3 x 0.02 = 2.16 x 50% = 4.32?
  10. B

    Recommendations of builder to do "shell" loft conv

    There are builders who are happy just to work on day rates but i am up in leeds so bit far to travel for the guys i know.
  11. B

    Getting the right size wood burner.

    1950's got cavity walls done, upvc windows, upto current regs loft insulation etc.
  12. B

    Getting the right size wood burner.

    I need some advice on woodburners. I live in a smoke control zone so i need a defra approved stove to burn wood, the room size is 44 sq mtrs with normal height room 2.4m. Ive used online calculators and it comes back with the average of 7kw required BUT what it does say is that, thats the...
  13. B

    Kitchen layout

    I have a seperate hall with the stair case in, already thought of that one. I will never be picking or turning with a pan as my wife is a chef so thats her job, thanks for the thought tho. The fridge wont be moving as ive built it into the wall already.
  14. B

    Kitchen layout

    Not if you fit all three down the same side of the kitchen?
  15. B

    Kitchen layout

    The room will be pretty big 9 mtrs long x 6 meters wide at its max, as making the downstairs open plan. Ill be doing all the work so its no more work plumbing the sink in the middle v's cooker (gas safe also). The extractor is the other thing with it hanging down in middle, the outlet pipe...
  16. B

    Central heating not working but Hot water okay

    The power to the pump comes from the divertor valves end switch when selecting htg mode.
  17. B

    British Gas boiler fix OK?

    BG dont make the regulations they just enforce them as does (or should do) everyother gas safe engineer.
  18. B

    Kitchen layout

    Yeah i know what your saying always come up that triangle hence why i was going to add sink or hob to the island, or would be hob and sink on same side then prep area on island.
  19. B

    Kitchen layout

    Im planning my kitchen area of my build. I cant decide if the island in the middle would look best with the sink or hob/oven fitted in it. Only thing with hob in middle is extractor hanging in middle then running the pipework to outside. What you think?
  20. B

    british gas rc plus

    Have you got these? http://www.gasapplianceguide.co.uk/DigistatPlus2.pdf