    Triton as2000xt dripping

    Hello Today I have been trying to fit the above named shower. I fitted one, and when I tested the pipework i found that the unit was leaking just above where the inlets are. Faulty unit i thought. I exchanged the shower for another connected the water and hey presto, another leak in the...
  2. D

    Valliant Boiler Hissing Repeatedly

    I have raised the pressure. It is still hissing every second or so. What should i try next? It's started doing this noise over the last couple of weeks. Everything seems to be working CH and HW still feel as hot as before.
  3. D

    Valliant Boiler Hissing Repeatedly

    Hi, we have a valliant boiler that has recently started to hiss about every second. The boiler's stat has always been set to full (position 9). When up to temperature the flames go out and the hissing stops. When hot the pressure gauge rises to 1.5bar. Any ideas why this is? Here is a...
  4. D

    Joiners 'repair' of door threshold

    To be honest that frame needs replacing. What did you ask/tell the joiner to do? If it were me and you had told me only to replace the threshold, I would had told you that the whole frame needs doing. The repair you have had done there won't last very long, it will be weak as it is not...
  5. D

    lowering a ceiling

    2x1 batons would be fine as long as you fix them through every joist above. Start around the outside of the room first making sure each baton is level with the lowest point in the existing ceiling, then fill in the middle at (I always use 400mm centers, but less is okay depending on board size)...
  6. D

    Bolier doesn't always fire up!

    So you think the problem may well be in this area.. I'll strip it on the weekend and go from there. Thanks for now though. If I need any more advice I'll resurrect this thread.
  7. D

    Bolier doesn't always fire up!

    I have found the microswitches (see pic). It looks like they are operated via a sprung plunger by a diaphram. With heating demand only the plunger moves towards the microswitches and when both are depressed the boiler will fire and heating runs. All fine there. Now. With the heating on...
  8. D

    Bolier doesn't always fire up!

    Front and side removed. Looks like its had a small leak in the past, no leaking now though. Also have just noticed that the temperature gauge is missing.
  9. D

    Bolier doesn't always fire up!

    Well I don't take them apart every day obviously. I have a rough knowledge of how the boiler works. I have the repair manual here, which I can flick through if needed. I am a tradesman, have been for 18 years, not gas, but you do pick things up along the way. In my spare time I've rebuilt...
  10. D

    Bolier doesn't always fire up!

    Any Guru's here that could talk me through?
  11. D

    Bolier doesn't always fire up!

    I'm quite handy.. :wink: I just need to know where to start. I'll start there.
  12. D

    Bolier doesn't always fire up!

    When cold it sits at 1 bar, when it 'is' going it rises to 1.5 bar ish. D
  13. D

    Bolier doesn't always fire up!

    No body here can answer?
  14. D

    Bolier doesn't always fire up!

    http://i123.photobucket.com/albums/o301/dan83590/Boiler/Image0027.jpg http://i123.photobucket.com/albums/o301/dan83590/Boiler/Image0026.jpg
  15. D

    Bolier doesn't always fire up!

    Hello I have a problem with my combi boiler I think. When the heating is switched on the boiler doesn't fire every time. It also doesn't fire everytime after hot water is used. With a demand only for hot water the boiler fires up every time. Is this going to be something...
  16. D

    Lighting circuit - Earth Problem?

    That could be said for any purchase any time, anywhere. We had a decent enough survey done, and the property was rented before so you would have thought things like the electrics would and should have been properly looked after. Sometimes you just have to trust people....
  17. D

    Lighting circuit - Earth Problem?

    It was a rented flat for years before we arrived. We purchased it a few years back. Everything you do here opens a huge can of worms. All this earth business is no surprise to us. Thanks for your help chaps, i'll get some quotes for a repair. :roll:
  18. D

    Lighting circuit - Earth Problem?

    The lighting circuit does have an earth wire inside the cable but it's not connected and in most places it's been cut so short it could not be connected. I haven't traced exactly where the cables go yet but it would be my guess that they run up 3 floors through an old lath and plaster stud...
  19. D

    Lighting circuit - Earth Problem?

    Reading through it now matey. Thanks for the link.