    Vokera Flowmatic boiler fault help

    its running at 1.5 bar but i dont have the manual to it dont soppose any one has one on here they could email me have they. thanks. cant understand why it should be overheating unless the overheat stat is nackered. thanks for the reply DP
  2. S

    Vokera Flowmatic boiler fault help

    Hi all, Have a problem with a Vokera flowmatic combi boiler. Symptoms are: Rad needs bleeding on a regular basis and boiler is now making loud banging noises when calling for heat and hot water. Both hot water and heating are still working but water temperature is scalding hot so due to...
  3. S

    celtic ff

    Your a star, send me an email with the price you want as the old dear is frezzing and needs it pronto.
  4. S

    celtic ff

    email me on with a price for pcb mailed to me but prior please send your boiler model. Ta, cocka make it cheap its for an old lady widow with 45 grand kids and xmas is comming up _________________________________ Moderator email address removed, these can be shown in your...
  5. S

    celtic ff

    Does anyone know if the spark generator is fixed to the pcb as it is nacked and if so will i have to change the whole pcb to replace
  6. S

    CELTIC FF

    Having a bit of a problem with a CELTIC FF combi boiler in trying to get the boiler to fire up:Turned switch on front to hot water and heating :pump runs.I then press the ignition button in for 15 seconds as instructed but pilot doesnt light once i release the ignition button the fan comes on...
  7. S

    Fitting a cooker gas hob the correct method

    If you dont ask you dont learn
  8. S

    Fitting a cooker gas hob the correct method

    Could someone please tell me what is the corrct way to fit a cooker hob. Some say it is ok to use a cooker hose as long as the hose is not subjected to heat more than 70c and others say copper pipeing must be used with an isolation tap fitted. If copper pipeing is the correct method, what...
  9. S

    Asbestos in domestic gas appliances

    Yes i am corgi reg thanks for the info i will check out the site thanks for the info :oops:
  10. S

    Hot rads downstairs cold rads upstairs

    Ok kev thanks for the advice, will start playing a bit
  11. S

    Hot rads downstairs cold rads upstairs

    By this i assume you mean from mains tap to rads and drain off vior rad drain off valve. Only problem is their are no drain off valves fitted except one fitted to the glow worm boiler. so that would be a problem.
  12. S

    Hot rads downstairs cold rads upstairs

    I thought that so ive fitted a brand new pump and still the same, like i siad the only thing i can think of is the system is blocked with sludge or an air lock. Might be better to get a power flush to remedy the problem. Expensive but i have tried everything else i can think with no joy. As...
  13. S

    Asbestos in domestic gas appliances

    Does any corgi guys out their know where i can find a list of domestic gas appliances that have asbestos in them and what is the correct procedure when you come across them. Apparently gas appliances with asbestos in them should not be serviced or worked on. Thanks
  14. S

    Hot rads downstairs cold rads upstairs

    It makes my girlfriend scream and she never complains so i assume its big enough lol. But more about the plumbing side lol, well the header and is just above the two radiators in the attic bedroom which is about 3 foot, i know this is low but the system was working perfectly until last week...
  15. S

    Hot rads downstairs cold rads upstairs

    Got a problem on a heating system with hot rads downstairs and cold rads upstairs its totaly baffling me. The system has a total of 11 rads, 6 upstairs and 5 down. The system is fitted to an open flued Glow Worm floor mounted boiler which has been their for years heating the house ok. Last...
  16. S

    Fitting a new central heating pump

    Thanks for the help got hot water to all rads apart from one which it seems after me draining the system sludge from the rad blocked the rad valve so after a few bangs on the valve hot water came through so everything is fine. Thanks again for your help.
  17. S

    Fitting a new central heating pump

    After refilling system im having problems getting water to upstairs radiators due to i assume air locks in the system. I can hear air rushing around the system when its hot. I have tried closing off all rad valves apart from one rad generating all the heat onto that one radiator but all i...
  18. S

    Fitting a new central heating pump

    One of the pump gate valves is also leaking so i might as well change both valves so it looks like a total drain down and refill of the system. Was wondering what is the correct method of draining down the system to fit the pump and gate valves then to refill avoiding any air locks. The...
  19. S

    Fitting a new central heating pump

    Im exchanging a central heating pump due to it leaking, could some kind sole explain the correct way in draining down the system to fit it. (External pump from boiler) Optional I have heard you can buy some freeze spray in a can that freezes the water in the pipework, this im told can be used...