  1. J

    Hive thermostats

    I'm not familiar with those Poly Pipe thermostats, maybe someone else is?
  2. J

    Hive thermostats

    You can get a wired up version of the Hive thermostat that would make it easier to just swap your underfloor heating stats, (so long as they are just standard mains powered thermostats and not some type of low voltage ones that send data to the control centre rather than just switching on and...
  3. J

    extractor fan wiring problem

    It there a voltage between brown and grey? If so then the grey is neutral (as it should be anyway) and black is switched live.
  4. J

    Thermostat wiring

    I take it you are talking about a cylinder thermostat, if so then terminal 2 will be the satisfied connection which is only required on a Y plan system and not needed on a S plan.
  5. J

    Pipe stat not turning pump on (3)

    The stat is wired wrong. The middle terminal is 1 which the brown wire should be connected to. Then the black wire should be connected to 2 (left) if you want the pump to stop at the temperature the stat is set at. Or 3 (right) if you want the pump to start.
  6. J

    Randall 922 replacement

    Sorry I was mistaken.
  7. J

    Hive heating operating problems.

    If you go into manage devices in the Hive app and select your thermostat there is a setting called "ready by." If you enable that, then the Hive will calculate how long it takes to reach the required temperature at the time you want. So if it is a mild morning it will come on later than if it...
  8. J

    EasyControl Wireless on Greenstar Si Compact

    It can't it's for the newer Greenstar 4000/8000 model boilers.
  9. J

    Hive Single Receiver - Final Connection

    If you look in section 13 commissioning you will see there is a setting "E" for remote control parameter it will be set to 1 at the moment you need to set it to 0. It is showing an error because when set to 1 it will be trying to connect to the thermostat that you have disconnected. Then...
  10. J

    Back boiler issue

    You probably have what is known as a gravity hot water, pumped heating system. When you turn the hot water on on the clock it just fires the boiler up and as the water in the pipes heat up. The hot water will rise causing it to circulate by gravity heating up your hot water cylinder. When you...
  11. J

    Why neutral at other switch?

    It's that long ago I can't remember.
  12. J

    Why neutral at other switch?

    We were told it was how you would make an existing one way switch circuit into a two way switch circuit. But also new circuits could be wired that way too.
  13. J

    Air source heat pump keeps tripping rcd

    It's more likely to be the pump because the actuators only have live and neutral to them, they don't have an earth, so are unlikely to trip the RCD.
  14. J

    Why neutral at other switch?

    I was taught the "conversion method" in college in 1983 and that is what we were told it was called. We were also taught the "conventional method" with feed at one switch and load at other switch with 2 strappers between them.
  15. J

    Fitting wireless thermostat

    Red and blue are right but yellow goes to NO and you need to put a link between L and C.
  16. J

    Replacing underfloor heating thermostats

    Heatmiser neo-stat V2 but at about £55 each and £150 for the hub it won't be cheap.
  17. J

    Wiring Drayton Wiser

    It's probably knackered so someone has just joined the wires together to get the heating working. On your new controller:- Blue to N Brown to L Black to 1 Grey to 3