    No Water From Hot Water Taps

    Tight git removed the rads, never had it serviced I guess? You would be lucky if it's just 80 euros and doubt it's five mins work.
  2. J

    Toilet not flushing away contents effectively....

    The tc loos have a interruptible flush press an hold the flush and see what happens then, if not could be that the pan has been made faulty and that the water can't shift down the sides and just comes out the front and back
  3. J

    Message for SUSIEJB

    Hi looprevil I don't want a tug of war either but alot of boilers now I do the same as bg and have tight t&cs and do the same type of contracts as them, I also do a free service for a new install and then do a contract with them after the second year as it's the only way to get breakdowns now...
  4. J

    Message for SUSIEJB

    To the OP you say it's a bargain but you have still payed £339 for your fix and nothing will go wrong in a year if it does it will only be small. So not a massive bargain, also read the terms of your contract, I have three old bg customers that paid like you and now there boiler need to be...
  5. J

    Vaillant & Wilo Pumps

    Vails use grudfoss are you sure it's the pump?? Has the sensor for the pump been tested assuming boiler model? I know the modulating pumps on them rely on the sensor of you get crap in it then the pumps burn out or stop working correctly. Again assuming boiler model! Did have one pop on one in...
  6. J

    glow worm 30 cxi f5 fault

    Maybe pump, thermisters or filters. Either that it will need a real powerflush. Worst case power flush and heat exchanger.
  7. J

    JG Speedfit - is it rubbish or am I?

    Plastic is turd that's why. If they leak at first it may leak later in life. Ten year guarantee? Try and get a pay out for this junk plastic and it will be your installation that made a fitting of 3years solid pop off. DIY or emergency use only I say. But that's my opinion.
  8. J

    Underfloor heating long winded as far as I can see

    Polypipe do a overlay system now shed loads better fitted it to alot of places always better then the screed type. Sceed type for newbuilds as with most ufh
  9. J

    servicing woes

    I'm in no way standing up for BG here but the test point from the internal point is only for the flue if it is a rear entry flue if it is a flexicom hx not a ultracom hxi! If the boiler dosent have a rear flue and has a top connection flue then they a using the FGA correctly. But on a different...
  10. J

    Betacom 30: hot then cold DHW prob.

    Classic, not to be horrible but that's the problem with the cheap units they are a throw away unit, had to fit a pcb to one of these heaps £173 plus fitting. Just a word it anybody reads this who is thinking of going cheap get a cost on parts before the money is spent out or as you have said it...
  11. J

    haltead ace high leaking

    Hi this would be a faulty auto air vent need a new one for it, but it's within the combustion chamber so would need a gas safe engineer to do it. Cheers
  12. J

    'Best' Boiler ?

    Hi its not so much the boiler as the installer. There are obviously better boilers than others but your main objective is to find a good fitter.
  13. J

    Permanantley remove micro bore radiator

    Yes you can cap micro bore if you can't find the manifold then cap them at closet part they come from, I always solder microbore caps as connex get a little movement they leak.
  14. J

    Transit engine??

    Cheers chaps no none of the story is missing don't think it's over heated no idea as they don't have a temp gauge on the LPG vans. When on petrol its super thirsty £1.30 a mile put £20 in get 20miles I'm not joking. That's why I ask how you test the injectors?
  15. J

    Transit engine??

    Hi I have a for transit 2.3 dohc petrol engine with LPG conversion does anybody have any idea if piston 1 is low on a compression test and oil in the water would it be the head gasket, cracked liner or bust valve? What can I do to test these? Has anybody got any advice for what could have caused...
  16. J

    boiler not firing,return blocked???

    Hi I would recommend to get the fitter back and change the flow and return pipes over as if it is a older system then it may of had a non return valve on the return and if the fitter didn't mark pipes off the old boiler he could of connected the flow to the return and the return to the flow this...
  17. J

    NO HOT WATER FROM HEATLINE COMBI BOILER

    Throw it away they are a bottomless pit. The diverter sound at fault but they are probably half the original cost of the boiler. Don't think British gas cover them on there home serve cause they are that bad.
  18. J

    Biasi combi - no hot water

    Reading it back I would say the thermister but on second glance it may be the motor on the diverter if the pin contacts the micro and the diverter motor dosent switch easy to check pop the motor off and see it the pin inside pops out!