    New light for xmas! But how to fit it...?

    yeuch - that would look rubbish! Just do the job properly with a jb
  2. S

    Adding sockets to downstairs ring + possible spur query.

    that looks fine and yes you can bring one spur off the ring Two points: How do you know that it IS a ring - just coz a socket has 2 cables it doesn't necessarily mean so! If it's not a ring, you could just be adding spurs on spurs which would be a problem if the fuse/breaker is 32A Is...
  3. S

    chandalier light goes dim as you add more bulbs

    one of the switches isn't a dimmer is it?
  4. S

    How many LV lights in a lounge, guidance needed

    I agree - not good lighting for a living room Why not go for a nice central light and then use table/floor lights to supplement eg for reading/atmosphere. You can wire special lighting plugs to these and fit lighting sockets on a switch or dimmer - quite classy (even if I say so myself) - I have...
  5. S

    cutting bus bars - how do you do it?

    I use these http://www.tlc-direct.co.uk/Products/BHJ1307.html
  6. S

    Earthing Spike and RCD

    Fitting 1 RCD upfront of your fuse board is a rough solution - if it trips you loose all power and all lights. If I was your sparky I'd be upgrading the fuse board to dual RCD or even all rcbo's. To do board upgrade I'd need to test all circuits to make sure there were no faults (such as N to E...
  7. S

    induced voltage - when is it not??

    thanks for replies folks - you learn something every day, eh? The voltage I was getting was on the load cables of a light, so not accessible and I was getting no glowing when the light off but the other switched on Cheers SB
  8. S

    Socket's and Mini Trunking

    oooh, yes Chri5, forgot about that one... often times if you sit it on the top of the skirting you can hardly see it - unlike conduit and the saddles...
  9. S

    Socket's and Mini Trunking

    The ONLY problem with conduit is that dust, fluff and dirt collects around the back and saddles. Trunking is much easier to keep clean SB And yes, I'm female......
  10. S

    induced voltage - when is it not??

    thanks spark123 So now I see why it might go up when I switched on a light, but I suppose I should have asked - is 60V OK and nothing to worry about?!?! I am assuming of course that it WAS induced - how can I tell? Would I be getting 50 Hz on mains and 0 Hz on induced??? SB
  11. S

    induced voltage - when is it not??

    Hi all Just wondered if there is a level at which induced voltage becomes real voltage? Is it 230V? Job today where I was getting 60V on a lighting circuit when a light on another circuit was switched on. And 11V when off. The cables run out of the fuse board together for some distance as...
  12. S

    Recessed spotlights

    You can get plates to cover the holes and then fit GU10's - but think these only go up to 120mm http://www.tlc-direct.co.uk/Main_Index/Lighting_Menu_Index/Lighting_Downlights_Index/Downlight_Converter_Kit/index.html I have in the past fitted bigger ones, but can't remember who made them -...
  13. S

    Tracking down non standard size T5 fluorescent lamp, please!

    Hi Rocky I'm getting power at the fitting - door opener switch - just had to keep my finger on it to keep it off! Thanks SB
  14. S

    Tracking down non standard size T5 fluorescent lamp, please!

    ARRGGGG The screwfix ones arrived and DESPITE me phoning them to check the dimensions they are the wrong size. Will try the other suggestion as they have both dims on the listing Thanks folks SB
  15. S

    Tracking down non standard size T5 fluorescent lamp, please!

    thanks for suggestions folks. Have ordered the ones from Screwfix Cheers SB
  16. S

    New light fitting - Confused.

    yup SB
  17. S

    Tracking down non standard size T5 fluorescent lamp, please!

    Rocky - I heart you! Those are the exact dimensions - not sure why I was convinced it was a T5... Secure - yes well annoying that there's no 'standard' size, but I think Rocky's found a match Many, many thanks SB
  18. S

    LED Lightbulbs - Flickers and goes out (1 out of 10)

    is it on a dimmer? This might be causing the problem.... If not then it must be the fitting. Try one of the bulbs you know is good fro the other lights and see if you get the same problem. Make sure it's screwed in nice and tight
  19. S

    Tracking down non standard size T5 fluorescent lamp, please!

    thanks peeps fr replies The screwfix one is with the pins, so too big :( Will advise on replacements
  20. S

    Tracking down non standard size T5 fluorescent lamp, please!

    Hi everyone A customer needs a new lamp - Its a T5 6 watt for under cabinet fitting. BUT it's not the standard length I've tried searching on line, but didn't get very far. I think from memory that MFI used to supply odd sized ones, but they're bust now... The lamp length end of pins to...