    Leak on a small section of tiled roof

    Personally I would take back enough to pull the only section out ( membrane is like 1 mtr wide strips pull that out and put a new one in. but to be clear you shouldn’t really be replying purely on the membrane to keep it water tight. That’s the tiles job. if it’s at the eaves I would put some...
  2. M

    Leak on a small section of tiled roof

    Is there any chipped / lifted / broken tiles you can see? you might be able to find it as it will be wet esp with all the rain we’ve had today. You can just insert some membrane you need to lift the lath off and replace the whole section.
  3. M

    Leak on a small section of tiled roof

    Is it leaking above the window? How old is the roof? It might be the felt at the first row has gone and water getting in that way
  4. M

    Does this eaves detail look right

    Catlad what’s wrong with it.. it isn’t 10 degrees... it is 14.7 degree. the way I’ve cropped the photo makes it look a lot flatter.
  5. M

    Does this eaves detail look right

    No I don’t think so, I would say more the fact the shear volume of water / speed. i have turn the main roof outlet to the side but still have an issue.. i need to restrict the follow I think. Maybe block the end of the Down pipe from the main roof and drill some holes to make the water come...
  6. M

    Does this eaves detail look right

    What you mean by trough? If you mean the water go over the edge.. my issue is that our house and next doors have one down pipe and unlucky it falls onto my extension roof, so when it rains heavily my god the amount of water is horrendous. I could try and higher the gutter up again.
  7. M

    Does this eaves detail look right

    Angle of camera mate, it’s defo 14.7 degrees, just doubled checked with the velux roof app
  8. M

    Does this eaves detail look right

    Firstly the water from the main roof is over shooting in heavy rain. Also now got an issue that some water is dripping out the soffit. yes it’s a Marley melodies down to 12.5 degree just think as it’s a rolled tile the first tile doesn’t keep blown water out.
  9. M

    Does this eaves detail look right

    Hi all, im having a right nightmare with our low pitch profile eaves detail (roof 14.7 degree) From the photo does this look ok?
  10. M

    Weird shadow mark

    Hi all, We had our kitchen tiles roughly 10 days ago with white 600 x 600 porcelain tiles, we have Electric UFH, I wait the 7 days before turning it on. I notice last night there we have some form of dark shadows appearing on the tiles. It can’t be a leak as we have no pipework in the floor...
  11. M

    Pitched roof

    Surely if it’s an unventilated roof.. you don’t have vents, BC can’t tell u to do that otherwise ur asking for issues.
  12. M

    Pitched roof

    Agreed Woody, he has already passed the roof and pre plaster. he only has completion to do.
  13. M

    Pitched roof

    Notch 7, I took a plasterboard down on the ceiling to move a cable prior to it been skimmed yesterday and when I pulled the insulation down the breathable membrane was wet on the underside. the windows are in but no heating and it’s a bear shell. It rained a lot when the building was being...
  14. M

    Pitched roof

    It’s a single storey rear extension. There isn’t suppose to be vents with breathable membrane and the pir insulation according to the internet. Although I have been about brought some soffit vents (70mm dia) to add a bit of cross flow. Although technically it should need it.
  15. M

    Pitched roof

    I’ve recently had an extension built, it has a pitched roof (vaulted ceiling internally) we have a 14.8 degree roof with a tile that can go down to 12.5 degrees (Marley melodie) we have gone for a 175mm x 50mm TR26 engineered timber rafter (Fully designed roof) with 150mm PIR insulation in...
  16. M

    Cable thickness

    What does that mean. I can I get away with the oven and hob on the same circuit? I can sort the combi oven
  17. M

    Cable thickness

    Whall3y sorry I don’t understand.
  18. M

    Cable thickness

    Hi all, I’m currently doing a new single storey extension which will become a kitchen. We have a 6mm twin and earth cable from the board (on its own 32amp) would this provide the necessary power for the following oven - 3.6 Kw Induction hob 7.4 Kw Combo oven - 3.6kw can the oven and combi...
  19. M

    Water over shooting rear gutter on extension

    I will move the gutter up first as it’s incorrect. Yes the down pipe was not connected while they were building and it rained... the picture is a couple of weeks old.
  20. M

    Water over shooting rear gutter on extension

    I think my guttering needs raising quite a bit then! Hopefully that should stop it.