  1. A

    Using adaptable box to terminate SWA

    Hi My problem is I've purchased a double insulated high integrity Consumer unit. THerefore it doesn't bloody have any knockouts for terminating SWA. I'm going to fit an adaptable box so I can convert from SWA to 6mm T & E cable. Is this suitable for my urpose...
  2. A

    clamp meter for measuring ac volts

    Hi On my course we had it drilled into our heads that mutlimeters are bad and we should use one of these http://www.pat-services.co.uk/martindale-vi13700g-safety-voltage-tester-1864.htm. If say you found a junction box/cable randomly undernearth the floor. The most hands free approach to...
  3. A

    spuring off existing junction box wired in 1.5mm

    i think its 1.5 looks alittle too wide to b e 1.0. its just run through the cavity and the ceiling void so no conduit. its a 6a type b 60898. I think just to be sure i put some digital calipers just to be sure. I didnt see any markings. double check to.orrow. thanks for the heads up.
  4. A

    spuring off existing junction box wired in 1.5mm

    Hi I want to add a new light in the hallway. The cable that I've purchased is 1.0mm twin and earth. The existing lighting circuit is wired in 1.5mm. Can I just use the 1.0mm for the lighting? The elctrician that orginally did the wiring put the downstair + upstairs lights on one mcb.
  5. A

    accenta g4 - inhibit zone setup

    hi i have used zone1 for door contacts and then zone 2 for a pir covering the keypad and front door. i want zone2 as a inhibit zone do i need to set it as. a timed zone and inhibit zone? do i need to set zone 1 as anything[/code]
  6. A

    Fitting shaver unit in bathroom

    Hi my brother in law wants a shaver unit fitting in the bathroom. The shaver unit has a isolation transformer fitted on the back of the socket. There are no lighting junction boxes as far I know. I was going to run a cable from a double socket in the hallway then down rate it using an FCU...
  7. A

    Notify council of consumer unit change

    Yes I was thinking about that as am currently doing my 17th edition. Am conviently on chapter 4 Protection for Safety!! My consumer unit doesn't have a terminal strip for non rcd protected. It has a terminal for each RCD and then strip for CPC. THere is an empty spot at the top in the...
  8. Untitled

    Untitled

  9. Untitled

    Untitled

  10. A

    Notify council of consumer unit change

    Ah sorry forgot to mension the image in my album. Just noticed how attach it lol. So is this how you would distribute the circuit. This is what the building control officier said he wanted. I asked him "so you want a picture of the consumer unit, breaker sizes, cable sizes" He said...
  11. A

    Installation method Bs7671 for buried cables in walls

    Ah ok so long as I expose the brick underneath put cable in it's ref c yes?
  12. A

    Installation method Bs7671 for buried cables in walls

    Hi I'm just confused as to which method to use when the cable is channelled into the plastered wall then plastered over. Do you just assume method C (clipped direct)? For example cables for sockets are installed like this.
  13. A

    Notify council of consumer unit change

    1) Any fully qualified electrician want to supervise me on this project of mine? It's in Whalley Range Greater Manchester 2)I spoke to a building controll officer. he basically said he want a wiring diagram including breaker/ cable sizes. I specifically gave him that example and he said...
  14. 106 wiring

    106 wiring

    a rewire of my sisters house
  15. A

    Notify council of consumer unit change

    Hi I'm very confused as to what the heck the council want me to do. I spoke to the officer he said that I'm better of submitting full plans which is cheaper apparently. He said he wants a schematic of what it is am doing. So does he mean something like this...
  16. A

    Fluorescent luminaire for loft space - how to wire

    Hi am lv2 2330 qualified student. I looking to do a loft conversion for some extra storage space. I have already added an extra junction box of an existing one. I was wondering if the switching arrangement is the same as a ceiling rose i.e. loop, live and neutral. If not how would I wire it...
  17. A

    Segregation of badn1 and band 2 circuits - alarm panel

    Within the alarm panel there's a supply cable that runs in parallel with the pcb within the alarm panel. In the new onsite guide on pg 75 it says 50mm space. To follow this rule I was thinking of running the cable outside the panel in parallel to the bottom edge as far over as possible. Then...
  18. A

    Accenta G4 mini sensors not working

    nah just blow the fuse. The panel and sensors were fine.
  19. A

    Accenta G4 mini sensors not working

    yeah I've did again today because I was rushing so I didn't trim down the cable. So I blow the fuse because I had to trim it down
  20. A

    How much current can 1.0mm handle?

    The zone wiring for the sensors are on top of the supply cable since like I said it runs across the entire width of the panel to get to the terminal block feeding the transformer.