    Help....I'm under instruction and stage 1 in now complete...The missus wants me to box in the fireplace to make one of those "recessed features" so she can put something in it! Would appreciate a review my plan and confirm if it's gonna work....The inside of the fireplace is quite good condition...
  2. R

    meter tails != 25mm^2 PME supply (TN-C-S)

    Fair point, other advise appreciated. cheers, ~rlc
  3. R

    meter tails != 25mm^2 PME supply (TN-C-S)

    Cheers Lectrician, dwelling is candidate for increase in loading through adding an extension soon, I have two old wylex boards fitted, wire fuse, no RCD protection and sub-standard bondind - 16mm tails coming from meter into CU. SWA feed to garage ring + lighting circuit. Suggesting best...
  4. R

    meter tails != 25mm^2 PME supply (TN-C-S)

    so reading a little further......Table 54H tells me that the main equipotential should be >= 10mm^2.....so is it correct to assume that the earthing conductor should be >=16mm^2
  5. R

    meter tails != 25mm^2 PME supply (TN-C-S)

    Could someone clarify table 54G and confirm whether meter tails of 16mm^2 (OD~9.1mm) are acceptable. I'm assuming as they are OK as they are still specified in the table? Is there any reason to get these updated to 25mm^2 and if so what benefit is there? In addition, the protective conductor...
  6. R

    Missing tag/seal on main fuse

    two options as I see it : (i) you can call your supplier & tell them the seal is broken, request a re-seal or (ii) next time someone comes round to read your meter he will probably re-seal anycase if you mention it...I don't think there is much you need to worry about if you explain the seal was...
  7. R

    Is my test fit for purpose please experts?

    https://isswww.co.uk/productdetail.aspx?ID=4912&clickcatcher=mft1552glabel&gclid=COHN57Ci6okCFT4GQgod31dwKA ~rlc
  8. R

    Removing halogen downlights

    I picked up a box of "suckers" in B&Q after christmas - seems they use a similar thing for hanging decorations and the likes - works a treat - they also use similar things on the kids sun-shields used in cars.... ~rlc
  9. R

    kitchen rewire issues

    ....get yourself a wall chaser off ebay - (£50 or something like that) - don't let the missus catch you but use the hoover - hose over your shoulder to catch the dust - quick, neat lines, easy to make good - do it when shes out shopping :D ~rlc
  10. R

    Is my test fit for purpose please experts?

    Difficult to know what its capabilities without knowing more details, make model etc.... What measurements do you want to do with this equipment: 16th edition? Did it come with a calibration certificate? If I read OP correctly: the equipment is not capable of measuring <200ohms? Does it...
  11. R

    where to site downlighters in a living room

    As it's not clear what you dwelling comprises of - don't overlook Part B of the building regs : fire safety......if necessary consider buying the ones with integral firehoods as this will probably end up being a cheaper option...
  12. R

    mA/VA ??

    ...take a look at http://www.pcguide.com/ref/power/ext/basics_Power.htm it tells you all about 'apparent power', 'true power' etc....enjoy! ~rlc
  13. R

    Cables under floor boards

    an aside but may prove useful in future or for other readers....I used a priory nail puller for lifting floorboards.....brilliant! ....saved me hours....bit hard on the palms at first but well worth it .... http://tooltray.com/ViewProduct.asp?i=152261 ~rlc
  14. R

    Who to register with???

    Most of these will allow registration on a conditional basis with EAL Level 2 VRQ for Domestic Installers qualification, NICEIC is most common and will cost you around £417 for the 1st year. Note that you are then required to nominate suitable sites for assessment which can now be done after...
  15. R

    Supplementary bonding for electric undefloor heating?

    thanks....para (v) page 58.....Could I pull my "5 Day VRQ Level 2 Certificate For Domestic Electrical Installers (Part P) certificate" from my top pocket....erm back pocket...Hang on....I know its somewhere.....will check my tool box..........in order to do this work? Would I need to inform the...
  16. R

    MK 100A DP Isolator Switch is vocal

    Good old spinning wheel.....rest of house slowly moving to digital but metering hanging on. I would say it's similar to a relay coil 'clattering' when coil hasn't enough power to energised it but not that loud. I'm 99% sure it's the isolator switch and as there is a possibility of a latent...
  17. R

    MK 100A DP Isolator Switch is vocal

    Thanks RF Lighting - I will contact one first thing in the morning.
  18. R

    MK 100A DP Isolator Switch is vocal

    My MK 100A DP isolator switch occasionally makes a slight noise - it appears that it clicks or ticks for short periods of time....I noticed it when I was taking my meter readings and initially thought there was some intruder in the cupboard......on further investigation I located it in the CU...
  19. R

    Supplementary bonding for electric undefloor heating?

    Is it a requirement to provide an earth bonding mesh for supplementary bonding across electric uf heating (kitchen or bathroom floor based), the layered structure would end up something like this : Floor -> Adhesive -> underfloor heating (cable + mesh mat) -> adhesive -> additional bonding mesh...