  1. A

    Combination cylinder

    Hi can a combination cylinder have a extra cws fitted to feed dhw
  2. A

    pump for DHW

    Hi i need to increase the pressure on the DHW as there is insufficient head from the cylinder can anyone help with a relatively cheap option/pump. any help would be appreciated.
  3. A

    low water pressure up stairs

    sorry the shower is running off the main water, but is really low up stairs like i said there is pipe work everywhere including lead pipe. i was really asking wot option would be better a pumped shower or a shower pump
  4. A

    low water pressure up stairs

    Hi all the water pressure in a house i made a visit to is really low (1bar) up stairs and wont run the electric shower. the CWS is pretty much level with the shower head which i know isnt helping, also the pipe work pretty much alround the house is pretty bad compression joints almost every...
  5. A

    Trouble with Combi Boiler

    check the flow if the flow is too high it would be difficult for the heat ex to warm that amount of water, try slowing the flow through hot tap see if it is any warmer if thats the case you will need to reduce the cold water main or by Pressure reducing valve if it is found to be too high. the...
  6. A

    Rads Cold at The Bottom

    check that the rads have been bled and all rads balanced properly this can sometime get thing moving properly how old is the system
  7. A

    Boiler Overheating

    Hi What are the main things that can make a boiler over heat.
  8. A

    potterton netta heat 16-22 MK2 F

    Hi i went to have a look at a potterton netta heat yesterday as the previous gas engineer shut the tennants off due to a gas leak and couldnt find it. when there i found it as at the appliance and was coming from the flame failure area which indicates to me that the device isnt working...
  9. A

    Potterton Netta heat 16-22

    Hi i went to have a look at a potterton netta heat yesterday as the previous gas engineer shut the tennants off due to a gas leak and couldnt find it. when there i found it as at the appliance and was coming from the flame failure area which indicates to me that the device isnt working and...
  10. A

    Water coming from blow off pipe

    leaking all the time there is plenty of pressure in the expan vessel
  11. A

    Gas Flow

    Hi can some one explain simply why is it such a big problem and what will it do if the gas at the appliance working DHW mode is less than 18mbar as the appliance appears to be working fine
  12. A

    boiler in bathroom

    Is there any regulations concerning me putting a boiler in a bathroom it is a room seal appliance.
  13. A

    Water coming from blow off pipe

    water is coming fropm the blow off valve pipe outside the house, could this be the expansion vessel has packed up needs recharging.
  14. A

    Fagor Ecoplus FEB-20E

    Hi Ive been looking for a instruction manual for the above boiler the PRV keeps blowing off, could this be the expansion vessel has packed up. New to the buisness before any funny replies turn up Thanks
  15. A

    Thermostatic mixer shower

    Hi i am looking for a thermostatic mixer shower as cheap as poss but can be plumbed with exposed hot & cold pipes can anyone point out a good suitable model
  16. A

    SIME 110C FORMAT

    Hi all had another look at this SIME boiler. the rads heat when the hot water is run so i checked the micro switch to the diverter valve was operating and checked the pin was moving when demand for hot water was on and both looked as if they worked fine could it be the diaphram could be...
  17. A

    SIME 100 FORMAT

    Hi the radiators heat up when the DHW is ran could this the diverter valve. any help would be appreciated.
  18. A

    rads heat when DHW on

    sorry took so long to get back its a SIME 100 FORMAT
  19. A

    Heatline Vizo

    Hi just been to look at a Heatline Vizo, there is no hot water and no CH, when the boiler is switched to DHW the boiler lights for 30 secs then shuts down and the flame symbol with a line thru it is flashing. The diverter valve motor is making loud noise. Any help would be appreciated.
  20. A

    rads heat when DHW on

    When we run the DHW the radiators heat at the same time could this be the diverter valve