Search results

  1. S

    Galaxy G264 - Completely remove unused groups

    Hi Galaxy Guy, Yes I did do a 51.17 restart. I figure I must still have something assigned to those Groups somewhere than I've simply not found yet. Cheers -s
  2. S

    Galaxy G264 - Completely remove unused groups

    My original Galaxy Alarm was comprised of 5 Groups: A1: Main house A2: Workshop/Garage 1 A3: Garage 2 A4: Garage 3 A5: Shed I've since knocked down the separating wall between Garage 2 & 3 and also demolished the Shed. So now system looks like this: A1: Main house A2: Workshop/Garage 1 A3...
  3. S

    Honeywell AG8 manual

    Hi folks, I've lost the manual for my AG8. I've found an AG6 manual online but can't find the AG8. Are these these same? If not, does anyone have an AG8 manual in pdf they could send me please? Cheers -s
  4. S

    Galaxy 3 keyprox - disable chimes in garages

    System is a Galaxy G3 with 264 Main board upgrade . System is comprised of: * Group 1 - Main house with 3 MK8 keyprox * Group 2 - Workshop with MK7 keyprox * Group 3 - Garage with MK7 keyprox * Group 4 - Garage with MK7 keyprox Each time the main house is set or unset, the 3 keypads in the...
  5. S

    Siemens SSA61 0-10V radiator values

    So Basically I'm a complete dumbass. The SSA61's need to be fitted to the valve. Then once powered up they run the calibration. Once calibrated they work as they should. Lesson learned :) -s
  6. S

    Siemens SSA61 0-10V radiator values

    Apologies for the late reply on this topic. Work has dictated that I don't get to do fun stuff right now. Anyway an update: I picked up a Ballorex APR-40405 (0-10V wax proportional actuator) as a test. This works as expected (apart from the fact the control is inverted - an easy fix in...
  7. S

    Siemens SSA61 0-10V radiator values

    I've picked up about half a dozen of these to control my radiator valves. I'm modulating these with Crestron 0-10V controllers (DIN-4DIM-FLV4). Measuring the controller output these do indeed measure 0-10V exactly when modulating the valves but the valves do not operate. I'm using the supplied...
  8. S

    Galaxy G3-520 - Alert! Enter Code - then nothing

    Automation is Crestron. The Crestron Galaxy program has been running continually since 2016 with no issues except for a break in 2018 when I updated the processor to a later model. When all this started while I was away I initially got my wife to unplug the Crestron during fault finding. I've...
  9. S

    Galaxy G3-520 - Alert! Enter Code - then nothing

    So about 5mins after my last post it started again. I've now disconnected the Ethernet module and unplugged the RS-232 so now back to basics. When I went into engineering to remove the modules, it asked me confirm removal of the comm-04 module and keypad 15 (not 51) which I assume is part of...
  10. S

    Galaxy G3-520 - Alert! Enter Code - then nothing

    Hi GalaxyGuy, Ethernet module is E080-4. FW: 6.31. Galaxy is on an isolated Automation VLAN - not a busy VLAN. Although I have an SPI key I have no means of getting firmware onto it (yet) but I will look at updating the Ethernet module anyway if they are flaky. Only reason I put the Galaxy on...
  11. S

    Galaxy G3-520 - Alert! Enter Code - then nothing

    Guys, Many thanks that was a great pointer. I didn't realise there was a virtual keypad (makes sense though) I thought the address of 51 was a bit odd. I have six keyprox's on 1-00, 1-01, 1-02, 2-00, 2-01 & 2-02 so confused the heck out of me. I pulled the serial cable as this is linked to an...
  12. S

    Galaxy G3-520 - Alert! Enter Code - then nothing

    Greetings, Haven't been here for a while due to working abroad for a bit. My wife has been pestering me for a while now as she had to completely disable the Galaxy while I was away. This is a DIY install (unsupported) and has been working fine for many years. Recently we've been getting an...
  13. S

    0-10V wired TRV's

    Thanks Mark, I have PM'ed you. At the moment, I have a mixture of value bodies but will be replacing all of these. -slip
  14. S

    0-10V wired TRV's

    Hi muggles. I did look at the Loxone's but they are quite pricy at 75quid a pop. I may purchase one to see what it is like. If it's well made and quiet then I would certainly consider them. I will need 15 in total.
  15. S

    0-10V wired TRV's

    Anyone know some good brands of 0-10V TRV's? These need to be wired and ideally 24V ac/dc supply. I really like the look of the Honeywell M4410 series and these would fit my requirements but I cannot find a UK supplier for them on google. If anyone knows where I can get these or a suitable...
  16. S

    Door Force error Keyprox (Max)

    So I had another play with the faulty CP038. Took it apart and had a good look using my SMD Optical Assessment Device (magnifying glass) but could not really see any anything out of the ordinary. By this stage I had replaced it with another 2015 CP038 which is working fine. So I figured I'd add...
  17. S

    New Galaxy Dimension - a few questions

    I decided to ditch the Reason8 bell box - it was just too hideous to look at. The AG8 installed like a dream. I have a second AG8 on order now and this will connect into the P026. I took some advice off this board and purchased some Aico Ei2110e mains powered smoke detectors & the accompanying...
  18. S

    Door Force error Keyprox (Max)

    Hi GalaxyGuy, Thanks for the insight. I thought it a bit odd that I was getting a door force as I don't have any form of door control. I'll have a look at the chip and get out my surface mount repair kit :) Regards -slip
  19. S

    Door Force error Keyprox (Max)

    So it is defiantly the CP038 keyprox that is generating the error. Having run the system without it for 10 days with no issues - I put it back in the system and within minutes I got the DOOR FORC error. Had a look inside the keypad and there is not a lot in there that I can see would affect it...
  20. S

    PIR's & smoke detector recommendations for Galaxy G520

    Guys, Thanks for the recommendations. I have ordered 3 x Optex RXC-ST and will fit those in my Garages first and another 11 to follow in the coming months as I get infrastructure in place in the main house. Ultomoat many thanks for your in-sight and advice and I will be going the route you...
Back
Top