Search results

  1. D

    Running cable from ceiling, to wall for picture lights / sconce

    Tap the wall with your knuckle - you will hear where the solid parts are. I have been lucky running TV cables where I wanted them, but I had to change plans for the alarm system as there was just a mass of dab just where I want the cable runs to go and I didn;t want to patch a large area
  2. D

    Which Radiator Make and TRV / Lockshield?

    I have mechanical TRV - one I think is stuck open and the others are OK. I now have a mismatched set that might as well be changed when I change the rads or have the system drained down to sort the blockages
  3. D

    Which Radiator Make and TRV / Lockshield?

    Indeed not, but I am thinking of having a look at the pipes myself, so whist drained down I can swap a few over. I think the thinking was that if the rads are corroded, then it would remove the possibility of chunks of corroded material coming away and blocking again. Ah yes, good point...
  4. D

    Which Radiator Make and TRV / Lockshield?

    Question of two parts: With the on-going saga of cold / warm rads that a flush didn't fix (probably due to microbore and manifolds being blocked), it was suggested that at least some rads would benefit by being changed. This is a job that I can do myself, I feel. The bathroom and en-suite...
  5. D

    Number of cold radiators

    Just a question that has come into my head. Having had the Magnacleanse on the heating system, does it need to be flushed through with clean water before refilling and adding inhibitor
  6. D

    Number of cold radiators

    Would this be close to the HW tank? I have a feeling that there is something there but it may be just a manual valve to balance the system.
  7. D

    Number of cold radiators

    I think we have barrier pipe - I have seen a section of it and there is a darker ring . I am thinking large particles are in the system. I saw some when talking to the guy. There was some stuck to the filter that he showed me and he did say that with the lockshields only partially open to...
  8. D

    Number of cold radiators

    I think the heating guy said I had lazy returns so a blockage on those sounds probable. I am not really familiar with the Speedfit plumbing. Can these be disassembled and re-used?
  9. D

    Number of cold radiators

    If I can get to a manifold I might have a go at just flushing those affect pipes with mains water to see if I can clear them. Worth a try before pulling the hosue apart
  10. D

    Number of cold radiators

    That is my worry - spending mor emoney on something and getting the same result. I had my usual plumbers in a few years back for the same issue. They had boards (actually chipboard sheets) up in one bedroom and I think that there's a manifold in that area that would supply the bathroom the loo...
  11. D

    Number of cold radiators

    Well, just an update and request for thoughts. I had a plumbing company out yesterday to flush the system. I requested a quote for a power flush but the guys doing it did a Magnacleanse flush - not what I was expecting. They did get some sludge and metallic debris out and I saw bits passing...
  12. D

    Light switch wiring help

    Have you connected red to COM and black to L1 on switch 1, and brown to COM and blue to L1 on switch 2?
  13. D

    How did this happen?

    Neighbours had a replacement bay window fitted, but the roof appeared to have come away. I did not see how this happened so I am curious now. I expected to see timbers attached to the wall at least
  14. D

    Which Type of Boiler / System?

    I have a plumber sorted to flush the whole system. I think a manifold or two might be blocked so that needs sorting. I am not sure the good lady will wait until the summer to get the heating working properly ;) Heating is working in parts - two rads are cold, two are warm, others are toasty...
  15. D

    Which Type of Boiler / System?

    Conventional electromechanical thermostat and 7 say programmer with three periods per day. There's a 3-port motorised valve for HW / CH. Yes, gravity fed HW It would be interesting to know of options. I'm not particularly interested in smart controls, etc. About the only thing i might replace...
  16. D

    Which Type of Boiler / System?

    Yes, the boiler works fine apart from a bit of kettling. I think a full power flush will be needed as I believe a manifold is blocked and that feeds the two cold rads. I have noted that both of these have no hot flow as the valves are cold, and one rad that is warm has a hot valve on the flow...
  17. D

    Which Type of Boiler / System?

    MIght be worth a think. I briefly considered a combi, but we had a breakdown a few years ago and were left without heating for about 5 days. The immersion heater at least gave us hot water. Also, getting the HW from the combi boiler to the tank location to connect to the existing would mean...
  18. D

    Which Type of Boiler / System?

    That was my thinking to be honest. Get to a known good position before changing anything. A full clean should be part of the changeover, and this could uncover other issues but we deal with those if the arise. I think the boiler is OK - it runs and we get heat where the pipes are not blocked...
  19. D

    Which Type of Boiler / System?

    I have been having problems with cold rads (https://www.diynot.com/diy/threads/number-of-cold-radiators.652613/#post-6150056) so have been getting quotes for a flush as nothing has cured the problem. A couple of plumbers have suggested changing the boiler as the current one is 25 years old and...
  20. D

    Henrad Radiators

    @Exedon Any issues with paint flaking on the Kartell rads?
Back
Top