Search results

  1. M

    Pyronix Enforcer - Tamper Error /Admin password reset?

    Hi sparkymarka So these are the three devices in the utility. The battery in the shock that I changed a few months ago. The PIR (2x varta CR123) and the door contact sensor one varta CR123 (black one hiding at the top left) are pictured below. Can send close ups if if that helps.
  2. M

    Pyronix Enforcer - Tamper Error /Admin password reset?

    Thanks T1GERIII both the cover on the door contact and the PIR are back on and secured back by screw (along with their respective new batteries). I might take another look at these tomorrow, but it does seem odd that they both are flagging as tamper rather than low battery, then there is the...
  3. M

    Pyronix Enforcer - Tamper Error /Admin password reset?

    Hi All, So I have a Pyronix enforcer (with the WiFi module) fitted around 2022. Albeit I don't know who by, as we bought the house in 2024. I changed all the shock sensor batteries a few months ago and one PIR that was flagging as low, but not any of the other contact sensors or PIRs...
  4. M

    How to repressurise Vaillant ecofit pure ?

    Thanks, I did exactly that and all resolved now.
  5. M

    How to repressurise Vaillant ecofit pure ?

    Hopefully the attached helps? 1) shouldn't the valve I have circled be closed? 2) I have attached a close up of the valve on the right, that seems to be closed on both the toggle and then a seperate screwdriver slot? - Seems odd but perhaps not
  6. M

    How to repressurise Vaillant ecofit pure ?

    You are right, all my previous boilers were combi's. Whilst this one is indeed a system boiler connected in the same boiler cupboard to a megaflow type system, with diverter valves to independently control upstairs and downstairs. The model is ecofit pure 630. The only braided pipe I can see...
  7. M

    How to repressurise Vaillant ecofit pure ?

    Thanks, the picture has all of the pipes running to the boiler. Ultimately there is one turnscrew valve over to the left and one to the right of the yellow gas valve. Presumably it is those then ?
  8. M

    How to repressurise Vaillant ecofit pure ?

    So I just noticed my boiler is sitting at 0.6 to 0.7 bar and it should be closer to 1-1.2 bar. I looked at a few online videos but none seem to match my config. I thought the yellow lever would do something, but seemingly not. How do I get a bit more pressure into the boiler ? Thanks in...
  9. M

    Hole in lead covering

    Thanks I will thinking something similar, I will push as much of the lead back up and then seal
  10. M

    Hole in lead covering

    Hi All, I have just moved into a new property and noticed whilst up on a ladder this hole to the side of the lead roof (above a bay window). Annoyingly it is somewhat new, but a tile must have fallen on it. Any suggestions on how to patch it? There are no water leaks inside the property. I...
  11. M

    TV mounting advice for flat TV

    Hi All, We have just bought a house and it had a recent extension in 2022 (so will be modern construction methods). My problem is this, I have a 77" LG G2 ready to go on the wall but I have sockets already in place, on this model the bracket ount is at the top and the bracket is very flush...
  12. M

    Max draw on a ring?

    The MCB is a 32a for that thing (sorry my dad has been relaying messages to me, and every time it changes). So now I have looked there is a 63a 30ma RCD but the specific one for this circuit is a 32a MCB
  13. M

    Max draw on a ring?

    Thanks, I just realised I made a mistake in my description (and have now corrected it), it is a 63a RCD, presumably this will ok?
  14. M

    Max draw on a ring?

    Hi All, We have just moved into a house that recently had an extension built. Basically it seems that in the utility part of the extension, the wiring is connected to a 63a 30ma RCD in a new consumer unit. On this single ring, there are 3 double sockets. The way I plan to use the sockets are...
  15. M

    Washing machine on Vinyl or concrete floor ?

    We currently have a vinyl floor that extends to the back wall under the kitchen units. Is it best to cut the vinyl back so the washing machine and tumble dryer sit on concrete ? Or will it be fine on the vinyl? Thanks
  16. M

    Pyronix Enforcer - Finding a fault / Missing nut in sensor

    It is about 14 months old, and that must be what it is...nothing else makes much sense. I will message the sellers and see if that is the case.
  17. M

    Pyronix Enforcer - Finding a fault / Missing nut in sensor

    Hi All, I have just moved into a new property that has a wireless pyronix enforcer alarm. Now the first issue, I can't engage the alarm 1) It says 30 - Car "tamper on input" . So it seems this is either a loose case or a faulty battery, I naturally went into the garage and found a contact...
  18. M

    How bad/worn is this pointing/brick condition?

    Hi All, I am looking at a property right now and pre-empting some of the survey points. The pointing seems to be missing in small places and "interestingly" patched in other areas. Does this still look serviceable with a bit of gap filling, or not really and needs to be done. Equally this is...
  19. M

    Does this fuse box need to be changed ?

    Hi All, I am just looking at a new property and noticed the fuse box looked a bit old and surrounded by lots of older looking 'stuff'. How old do you think this consumer unit is and anything that worries you about it (apart from the wiring to my eye looking a bit unkept!)
Back