    flooring expansion gap around door jamb

    hi. i've paid for somebody to lay my oak flooring . The skirting was left on so i will be using 16 x 16 quadrant beading... My problem is that instead of cutting out the door jamb and placing the flooring under this, he has cut the flooring around the door jamb. this looks a little un sightly...
  2. C

    rcd triping when operating landing switch

    i suggested if this was a borrowed neutral apparently its a It is a back-feeding open circuit neutral as suggested by RF lighting. allthough this was on another part of the lighting circuit and not on the 2 way. as regards to part p i informed my labc and contacted my supplier who fitted an...
  3. C

    rcd triping when operating landing switch

    evening all, i have recently installed a new dual rcd consumer unit at my house. the old cu had cartridge fuses, one was a 5 amp for lighting upstairs and down stairs one 30 amp for sockets and one for cooker. i separated the 2 feeds for the lighting and connected on opposing rcd sides. one...
  4. C

    fcu' will not fit on dual galv back box

    very nice indeed, domestic kitchen? what size is conduit cut too inbetween boxs 25mm? and what you used to chase?
  5. C

    fcu' will not fit on dual galv back box

    yes i told tiler to tile up to the back boxs so switches sit on top, but didn't want him to carry on if i was to chase out wall to make more space for switches to sit together. initially i had 3 switches together and put in 3 single galv back boxs and used a laser to make sure they where...
  6. C

    fcu' will not fit on dual galv back box

    just measured the volex ones which are 90 mm 4mm extra on each side, so if i get some at 86mm should be ok and tiler can carry on tommorow.
  7. C

    fcu' will not fit on dual galv back box

    hi jus completing kitchen, i've used an mk galvanized dual back box for 2 fcu switchs, and 2 volex fcus from screw fix (which i've heard are poor quality) but i've found i can not screw these back as they are too wide. can anyone suggest any fcus that will fit this dual split back box . thanks
  8. C

    lighting wiring

    initially it was isolated, was investigating and realised it became live when switched. thanks so it is safe to place back with the neutrals ? what wiring method is this ?
  9. C

    lighting wiring

    hi, about to install some downlighters in kitchen. in the rose there is 2 single blacks together and one red with grey sheath (switchcwire). at the switch there are 2 single reds placed in the com and the red with grey sheath in the L2. im a little confused as one of the blacks at the light...
  10. C

    Rewire of house - currently vacant.

    galliano i can sympathize that this is a young family wanting their own house and not a flat and have a budget to work with. but to be an electrician is a skill, that can take years and cost an individual a lot of money to become one, and should be paid accordingly as you or anybody else in...
  11. C

    jointing an older piece of cable with new

    the older cable on ring is flat pvc the old colours of black and red i believe that it is recent visually looks in good condition allthough not been tested by anyone else.
  12. C

    jointing an older piece of cable with new

    exactly i agree. the reason i ask is because an electrician has made some points of why a friend needs to have a full rewire. one being "New cable connected with old" with this i presume he means jointing new with old. yes 526.5 type of connection, and wether it needs to be accessible reg...
  13. C

    jointing an older piece of cable with new

    is there a regulation that prohibits this :?: , ive looked through the regs but can not find any wording that suggests this.
  14. C

    halogen lights info

    thankyou for your time and expertise , much appreciated:wink:
  15. C

    halogen lights info

    Hi. firstly i have some old low voltage halogen recessed lights without instructions. each pack contains 3 with a transformer. i have 2 packs so would i use both the transformers in series. i know that if you have 2 batterys in seris the output would equal both batterys together. secondly i...