  1. L

    help! high water pressure...

    could have been a blockage which got pushed through, it would explain why your pressure was low and a load of crap came out :)
  2. L

    Which boiler?

    I don`t use wire wool, i thought he meant power flush like you`d do with an old system, i flushed the pipes with water before getting the boiler installed :)
  3. L

    Roughcaster, Can you help?!

    Strange for that to happen on new work, it can happen if you skim over old work and not unibond it, but for it to happen on new plasterboard is a new one for me. I would unibond and go over it with easy fill then sand that back.
  4. L

    Ideal isar he24 no dhw pressure

    Thanks guys for the help, turns out it was the plate heat exchanger, it was solid with lime scale.
  5. L

    Which boiler?

    System did not need flushing as everything is new, i replaced all the old rads plus pipework as the old stuff was mixed with steel pipes, the rads were around fifty years old as well i reckon lol. I`ll check the pump and try to balance it again. Thanks for the help guys.
  6. L

    Which boiler?

    Well i have tried balanceing it, but still the heat does not seem to get all the way around, nor do the ones on the end get very hot. The current boiler is a vizo condenser combi vizo24. I got it for £400 and was told by the guy who sold it it would be powerfull enough for the job. Now i`m not...
  7. L

    Which boiler?

    Hi guys, which combi boiler would you reccomend for a three bed house? it total they have 5 panel rads, 6 double rads, on towel warmer. Double rads are 2 1200x600 4 600x600, the panel rads are much the same sizes. Currently have a vizo fitted but the rads do not seem to get very hot on the...
  8. L

    Ideal isar he24 no dhw pressure

    Na no sentinal, it is a rented property and they keep maintainence and costs to zero i reckon :)
  9. L

    Ideal isar he24 no dhw pressure

    Cheers dan, i`ll strip down the valves and make sure they are clean, @idealnumber1 do you mean the iso valve connected to the boiler or the one on the feed loop? The feed loop is working ok.
  10. L

    Ideal isar he24 no dhw pressure

    lol ya the stopcock is open, cold water pressure is fine
  11. L

    Ideal isar he24 no dhw pressure

    @idealnumber, They had no hot water when i got there and have had none for a week. Not a lot i can do about that. I changed the pump as the one in there was not running at all. Now it does :) @Dan_Robinson The filling loop is running just fine, i bring the pressure up to 1.5 bar so no...
  12. L

    Ideal isar he24 no dhw pressure

    Sorry ya, cold water pressure is fine and the valves are fully open, i am a plumber by trade but have not worked on this type of boiler before :)
  13. L

    Ideal isar he24 no dhw pressure

    I was called out today to look at the above named boiler, the pump was not running for the c/h so i replaced that and the c/h now runs fine, however the dhw has zero pressure at all, can anyone advise me on this please?