Search results

  1. lightning

    How do I adjust theses hinges

    Hello Problem I am having is a gap in bottom left of the door . There are four hinges . Make thanks
  2. lightning

    Transit custom 2016 washer pump

    Hello Trying to replace washer pump , removed headlight but can’t get to last screw which holds the washer bottle in place. Haynes manual saying I need to remove front bumper. The screw won’t come out or get to as front fog light in way. Any advice would be a massive help .
  3. lightning

    Fixing sleepers

    Hello I am doing raised beds with oak sleepers I am using the 125 mm base of the sleeper and going 3 high 600 mm I am using 250 timber lock bolts to secure Question should I cement in oak post on the inside to secure all 3 sleepers as it’s going to me 7 meter run Do I have to use oak posts...
  4. lightning

    Would this be possible

    Hello We want to join on to the extension We want to knock down the conservatory and make one big extension. Question would this be possible Both extend out by 4 meters Thanks
  5. lightning

    Mcb tripping

    Hello We seem to have delevloped a fault in the down stairs ring. We can use the tv, hair dryer standing lights sky but soon as we plug in say kettle , lawn mower it will trip. We had a out side light wired up through the garage consumer unit all work done by a qualified sparky and also a 3...
  6. lightning

    Hive 2 channel wiring

    Deleted
  7. lightning

    Vauxhall zafria 1.8 auto p1895 fault

    Car was running fine, put in new headlight bulb so had to remove airbox and bend it up a bit , now car is missing on tick over and sounds like its running on 3 cylinders fault code comes up above. any help paul
  8. lightning

    nice cheap boiler service not

    This customer payed £30 for boiler service 1 month ago, she didnot want to pay £50 + vat How much does your life cost???
  9. lightning

    Rcd tripped cant reset

    Hello Socket got a bit of water in ,from boiler change, which tripped the rcd, replaced socket and all has been fine for 2 days. Now mcb for sockets has tripped and well as the rcd,there are 2 sockets mcb, 1 stays tripped the other is fine. But soon as i plug in any appliance its...
  10. lightning

    Were to buy stationery eg cp12 forms

    Hello as title says for eg service stickers, landlord/safety checks,at risk labels , id labels Been told should not be using corgi cp12 anymore Cheers Paul
  11. lightning

    Still confused with wiring up a vaillant eco-tec

    This is what i have done so far. Took the live ,neutral and earth from 3 amp fused spur. screwed them into terminal into boiler {l/n/E} Took the old cable from the wiring center from live and screw into terminal 3 {removed link between 3 and 4} The other lead from wiring center which...
  12. lightning

    vaillant 615 eco-tec wiring

    Hello vaillant eco-tec 615 system boiler Have wired all stats and programmer up . Used a 3 amp spur which is wired in to boiler question is what terminals on boiler do i use to run to run cable up to wiring centre ,it is a y-plan
  13. lightning

    wiring a horstmann wireless stst

    Hello removing old room stat and replacing with horstmann wireless stat. wiring has got me a bit confused right here go's neutral go's to neutral heating on programmer to nc 3 way valve white wire to no there is a wire from com to live on stat does that have to be removed...
  14. lightning

    Rangemaster cooker keeps sparking

    Hello Have a rangemaster 110 cooker when the gas lights on the oven, the electrode carrying on sparking. I have clean the electrodes, but it still carries on sparking any thoughts Thanks
  15. lightning

    Flue Gas Analysers

    Hello Got about £650 to buy an analyer, thinking of a kane 455 pro kit. are theses worth there money or is there better model out there for the same price. Cheers Paul
  16. lightning

    Question about burner pressure

    Hello If i have a range rated boiler of 12 kw 15 kw 18 kw 10mbar 13mbar 16mbar if i check burner pressure and it comes out at 13mbar but gas rated it at 18.1kw. Then i am thinking that the injector is wrong size or has been enlarged . is this correct...
  17. lightning

    Solenoid valve on cooker

    Hello Electric stat for a cooker has reached its temp and has expanded the bellows and broke the switch to the solenoid valve, the valve should close shutting of the gas supply {down to by-pass rate} Right the question i am asking is 1 if the burner does not reduce when temp is...
  18. lightning

    Bit of help on cooker controls for acs in feb

    Vapour pressure device This type of device is commonly used on cookers and typically does not have a closed position. Instead it has a low fire rate, or bypass used to light a burner on low flame. The low flame is positioned on to the probe containing a volatile vapour. As the flame...
  19. lightning

    Dfe in a pre-cast flue

    Hello Some one asked me the other day why cant a DFE go into a pre-cast flue. So answers on a post card please
  20. lightning

    glowworm safety devices

    Hello Looking at glowworm 15kw hxi manual ,looking on seeing how the safety device would work and how quick it should shut the gas valve down.but it has no information in the manual at all?? very confused about that This is for a project in college . Also you cant check burner pressure...
Back
Top