• Looking for a smarter way to manage your heating this winter? We’ve been testing the new Aqara Radiator Thermostat W600 to see how quiet, accurate and easy it is to use around the home. Click here read our review.

Search results

  1. A

    Good reliable Traders

    I am after a painter and decorator to do some work on my house in Wolverhampton but I dont want to just keep ringing around in the yellow pages to try and find a good trader. I can find lots of information on rouge traders but is there a website/list somewhere that has all the good traders?
  2. A

    Building a garage out of Brick

    Hi guys. I want to build a garage 21 feet by 21 feet (roughly) at the bottom of my garden. I have never done any brick work before but am willing to give it a try. I am thinking of using breeze block as they look easier to work with. Currently the garden is slabbed with 2.5" slabs...
  3. A

    Cooker flex size?

    What size flex do I need to use for a 9000w cooker. The existing circuit in the house uses a 6mm twin and earth cable and a 32A MCB, do I need to change this to a 45A? I know 1.5mm flex is good for upto 3600w but i dont know about anything above this. I would have said i need a 6mm flex...
  4. A

    RCD keeps tripping

    I have a problem if someone can point me in the right direction that would be great :) When I turn the kitchen light on and off it trips all the kitchen sockets off at the consumer unit, the lights remain working?? There are 2 RCD's in the consumer unit, the light circuit is connected to...
  5. A

    help ive just put a screw through a pipe!!

    its one of the main (22mm i think) pipes that goes to the boiler. Ive turned the water off so it has stopped leaking but how do I fix it?? Would I have to replace the pipe or would i be able to solder the hole back up?? The hole has about a 2mm radius Cheers, Alan
  6. A

    noisy pipes??

    the water pipes for my boiler make a horrible tapping/ticking noise and its starting to get to me now. It only happens when the pipes are hot and its constant. Sometimes it starts with a slow ticking then it gradually increases then it will stop for a while. Is there anything I can do to stop...
  7. A

    cable size?

    Hi guys this is my first post on this site, i need some help please. Ive just bought a seperate RCD shower unit for a 9.5kw shower as the consuner unit is not RCD protected. It is a 63A 30mA RCD and includes a 50A MCB. What size supply cable is required from the consumer unit to the RCD and...
Back
Top