    Conversion of Shed to Workshop Pics

    Tidy work there Tom. I will be doing something similar to my shed in next couple of weeks. Is that T&G your using inside ?? What sort of price and where if you dont mind me asking ?? Thanks Kris
  2. K

    electric underfloor heating won't work

    Why "MUST" it? Because that quote was taken from the manufactures instructions. well not all of it but here it is taken from the manufacturers instructions. Undertile heating must be wired via an RCD. You must install a dedicated RCD, if one is not already present. You may wish to use a...
  3. K

    electric underfloor heating won't work

    What type of underfloor system is it??? Matt or the cable type ?? What was your sub floor preperation?? What size kit was it?? Was it wired via an fused spur?? The system MUST incorporate A 30Ma RCD either at the distribution board or by a dedicated RCD supplied from a fused spur...
  4. K

    Two Storey Extension

    Awesome work there pal. Any updated pics of how its looking now ???
  5. K

    Underfloor heating supply

    Here you go mate. Screwfix do them http://www.screwfix.com/prods/14770/Electrical-Supplies/RCDs/Powerbreaker-13A-RCD-FCU http://www.screwfix.com/prods/83049/Electrical-Supplies/RCDs/Volex-13A-RCD-FCU
  6. K

    Where's the cheapest place for Tiles???

    Pleasure mate. Let us know how you get on :) :)
  7. K

    Photos

    Top job there pal Well done :) :) :)
  8. K

    Wiring up underfloor heating - PICS ADDED

    Ahh, a true keyboard warrior. HOOK - LINE - SINKER HAHAHAHAHAHAHAHAHAHAHAHA
  9. K

    Where's the cheapest place for Tiles???

    I got all mine from Tile Giant matey. 400mm x 400mm travertines at £2.99 each as they are on special offer at the moment They look lovely on the floor and walls. Thing is you will have to get yourself a wet wheel cutter to cut them as they are 12mm thick but they do cut with ease...
  10. K

    Wiring up underfloor heating - PICS ADDED

    Now Now dont get your G-String in a twist Mr Keyboard Warrior. It cost me alot more than that, only put £100 cos i knew you would bite HOOK - LINE - AND SINKER HAPPY NEW YEAR :twisted: :twisted: :twisted: Topic Closed
  11. K

    Wiring up underfloor heating - PICS ADDED

    Friend of a friend BAS :wink: :wink: Oh yeah and 24 cans of carling :lol: :lol:
  12. K

    Wiring up underfloor heating - PICS ADDED

    All sorted now :D :D :D :D Sparky came round this morning and completed all works. He said i hadnt done a bad job and was on the right track but just needed a few tweeks to make it spot on. He never moved the fan switch in the end, all he did was fit another back box inline with...
  13. K

    Wiring up underfloor heating - PICS ADDED

    Cheers matey :) I will cut another hole in line with the studs and line up with the existing switch with the cables or at least within 15mm of them. It will be easier than re routing them as that was a ball ache. cheers Kris
  14. K

    Wiring up underfloor heating - PICS ADDED

    Mathew, Many thanks for your input mate and bringing me to light on the safe zone matter. Had a good look at the wiki and yep i was well out the safe zone until i remembered that i have a fan switch on that wall in close proximity of the cables so went up to bathroom and took some...
  15. K

    Wiring up underfloor heating - PICS ADDED

    Right, i removed the plasterboard in corner, opposite to switch in other room and located ring main and back box to socket Is there anything stopping me from spurring from this socket using 2.5mm T&E through battens and clipped, up through conduit with cold cables and into loft to the...
  16. K

    Wiring up underfloor heating - PICS ADDED

    John, Just got off phone from manufacturer, nice chap and said that i can spur off from an existing ring main (socket) and feed into loft space but it must be protected by a metal clad RCD - FCU unit I presume its one of these...
  17. K

    Wiring up underfloor heating - PICS ADDED

    Many thanks for all your help on this chaps. BAS, cunning as ever LOL, yep should have planned it better but **** it. Ive included some pictures to give you a better idea of the set up Click on pics to enlarge Consumer Unit Plaster Board cut away, 2 cold cables and sensor...
  18. K

    Wiring up underfloor heating - PICS ADDED

    No John, wasnt taking the ****, electrical is not my thing and to be honest im not sure what im talking about when it comes to electrics and jargon. Been a long day and got tiler coming in morning to lay floor and wall tiles and at the end of my tether. If i had hair then it would be all...
  19. K

    Wiring up underfloor heating - PICS ADDED

    Thought that would be the case with the junction box.Thanks for the info. The FCU will have to be in the loft by the loft hatch for easy access to it. The wire system is the smallest available at around 1.5 Sqm as bathroom is only small so will be fused at 3amp Whole house is protected...
  20. K

    Wiring up underfloor heating - PICS ADDED

    Direct cable from consumer unit to thermostat mate ???