  1. J

    Saniflo Sanicompact - who makes 10psi AAV 32mm solvent weld?

    Saniflo Sanicompact note that where the pipe discharge is below the floor level of the unit, an AAV (Durgo) may be required with 10psi rating. The discharge from the 32mm to 110mm stub soil stack is pfft, 100mm below finished floor level. An alternative option is for the drop to be in the...
  2. J

    flooring grade rock asphalt replacement - new DPM choice?

    Existing floor DPM: Flooring grade rock asphalt, perimeter shattered, messy repairs, few cracks. Brittle toffee, hessian underlayment, concrete slab, 1951. Being removed for shower area (Sika-1 w/proof screed over impey aquagrade w/duralay wp etc). Clearly the concrete will need a grind...
  3. J

    lathe services?

    In the past a few people had access to basic lathe services, anyone still around? Thanks.
  4. J

    Concrete raft 1950s - depth for pipe, asphalt over concrete

    I need to put a 22-32mm pipe in a floor. Build is 1950-52. Construction is 22-25mm flooring grade asphalt (brittle) over concrete raft. Raft appears to have a ring beam down to at least 24" from digging (concrete extends 24" below brick, so 225mm of brick above that to the concrete floor)...
  5. J

    Cavity Wall - wall tie, bridging, brick returns - photos

    Do the following preclude cavity wall insulation? http://i55.tinypic.com/s26usy.jpg http://i52.tinypic.com/t99i01.jpg http://i55.tinypic.com/rw5tty.jpg http://i54.tinypic.com/2yosdch.jpg http://i51.tinypic.com/ehhvn7.jpg Photos are taken looking UP the cavity, via a mirror held at an...
  6. J

    PIR on solid wall - roll-own w/Seconds or PIR+PB pricey?

    I need to insulate 4m^2 wall. The wall is solid double brick, pebbledash, 2ft eaves overhang. The wall sits between 2 cavity walls, with one cavity wall being just 3ft long where it meets a 2x4" mortar debris infill bay window w/pebbledash. The 4m^2 wall does not seem damp, browning under...
  7. J

    Lean-to roof repair - tiles on mortar / felt / mortar / wall

    Relative has the following lean-to roof... - Concrete marley etermit tiles on batons, felt, T&G close-boarded, rafters. 22-degrees. - Close-boards stop at the double-brick wall, tiles are then bedded on felt, on mortar, with mortar edging. Over the double-brick wall at a north-facing...
  8. J

    Anyone any experience with Pratley Klik-Lok IP66/68 Jn Boxe

    Anyone any experience with Pratley Klik-Lok IP66/68 Jn Boxes? Have used Pratley above/under IP68 boxes, never used their Klik-Lok. I have a relatively "lightweight" MS Jn IP56 close to the ground. - 2.4mm wall thickness, polycarb - CW glands w/sealing washers, piranha, drain hole drilled...
  9. J

    Duoheat - controls reliable ?

    How reliable are Dimplex Duoheat SH controls? - by that I mean the plastic control panel AND the PCB Anyone know the cost of replacement controls? - just so I know if infected by "crap gas boiler PCB disease" I will phone Dimplex tomorrow if time to find out. I was going to buy my...
  10. J

    Sockets with single pole switching - issues ?

    Relative has expressed interest in Clipsal IP66 (rotary) switched sockets, reason being... - Switch is external (not under a flap) - Switch is big & rotary - Switch is wet finger proof - Switch is usable with curled-in-fingers (can't recall medical term) - Switch is accessible without...
  11. J

    Niglon / Screwfix IP68 SWA Joint - lid does not require tool

    Niglon make an IP68 SWA Joint box. It's a round polycarb drum with perimeter steel plate to bond the glands without using banjo or earthing/piranha nuts. 4 way entry, use as you need. Trouser type or H box (like the rare Pratley) would be better. Either my eyesight is going, or the lid is...
  12. J

    Replacement of immersion element - issue re tank

    81yr old widow mother just lost her vented immersion heater element. - Element L-N 18.1ohms, L-E/N-E is 1000ohms & IR is 0.0megohms - Cabling IR ok, EFLI << 80%, R1+R2 unchanged, terminals ok System... - Element - probably heatrae sadia, 25yrs old, soft water (welsh). - HW tank - may be...
  13. J

    Is top entry by SWA CW into Masterseal acceptable?

    Is top entry by SWA CW into Masterseal acceptable? Bottom drain hole drilled. Bottom/side exit also in SWA. North facing wall, outside, end of a long cable run. Piranha obviously re plastic enclosure. Yes an SWA gland is IP68, but as far as I know it is a no-no because a) shroud is not...
  14. J

    Wiring zones, sloping chimneys & mechanical protection

    Complex room: - Chimney sloping out of wall in corner of a room - Corner zone thus ends below ceiling at base of chimney slope - Ceiling zone thus ends before corner at edge of chimney slope Current Installation - see Option-2 picture: - Current 2G boxes are used to mark cable route - CU...
  15. J

    Does a zone defined by CU/DB remain if placed in a cupboard?

    Visualise the corner of a room. - Loop-in PILC + Cutout + Meter + CU located on wall - One f.c. cable exits the CU - straight upwards in oval conduit - Other f.c. cables exit the CU - travel right through the wall Q - If a cupboard were built over the lot, does the CU zone remain? The...
  16. J

    Cooker Outlet Plate - Brand with least depth / most space

    Cooker Outlet Plate - What brand has the least depth / most space? MK uses a particularly large terminal block. - The block sits close to backbox top-entry holes - The block sits very close to the rear A deeper backbox has the holes at the same depth so gains little. Just wondered if...
  17. J

    Existing cooker f.c., Adiabatic calc & CPC size

    In replacing kitchen cupboards I had to re-arrange some tiles, underneath I spied some capping at a distinct angle! Exposing the run revealed cooker FTE at >5 degrees to the vertical with regulations requiring <3.5 degrees since 1987 IIRC. The capping had a notch out of it where the fitters...
  18. J

    Cooker cord outlet

    I'm looking (literally) at a cooker outlet which is surface mounted. - MK Logic Cooker-CU on MK 48mm white metal surface box. - MK Logic Cooker-Outlet on MK 41mm grey metal surface box. - Linked by 60cm nylon conduit (6491X 10mm PN, 6mm E, CPD 32A B RCBO). The problem is the plastic...
  19. J

    Best immersion safety-thermostat brand - Cotherm?

    Picked up a new (safety) thermostat at short notice. - No approval marks (no BEAB, no CE) - Only 12.5A rated (ok under 17th Uo is 240V, or 3.0kW) - Screw slots so thin had to file a jewellers screwdriver - Plastic lid so badly designed it partly obscurred terminals - Terminal hole just big...
  20. J

    Upstairs chimney w/ vented plug , only vented underfloor

    Chimney upstairs & downstairs flue have rain mushroom-plug w/side holes. Neighbour had chimney repointed by known good builder reported no chimney problems up top. House is cavity, no rendering, loft recently checked ok & insulated. Downstairs flue is vented. Bottom vent via gas fire which...