Search results

  1. S

    shower water going cold

    whats it like with other hot taps?
  2. S

    Fitting new boiler question

    thanks for your reply - i know i'm just wanting to know wha i'll be doing before i do so i can prepare for it. hang jig / pipe up to new connecions - run condensate and prv - prv outside elbow-street elbow in towards wall - flue (if allowed to) - all tightness test/commissioning i will...
  3. S

    Fitting new boiler question

    i have done plumbing work for 3 years or so and have acs qualifications - but have never hung a boiler before, so want to do well.
  4. S

    Fitting new boiler question

    ok thanks for your help
  5. S

    Fitting new boiler question

    ok thanks for your replies - I'll do what he asks me then, probably will get to do the condensate as well - i'm guessing screws will come with the boiler to hang them? otherwise what size is best? I really want to do well :)
  6. S

    Fitting new boiler question

    no I'm not gas reg but have done tightness test when helping an engineer before at services - i can do pipework, and have hung rad brackets - so just wondered if I'd be ok to help fit new boilers or if there was anything else i'd need to do or practice
  7. S

    Fitting new boiler question

    Hi I've been asked to help an engineer for a few weeks fit replacement boilers and hang new rads. I've fitted bathroom suites and ran pipework before, and done plumbing repairs, so was just wondering if I'd be ok helping to fit new boilers. I know what's roughly involved, ie fitting to...
  8. S

    Our boiler only works when we punch it!

    couldbe sticking diaphragm in switch or microswitch in aps - intermittent fault - could be ignition fault too/anything really - pump sticking??....
  9. S

    Testing a faulty Thermistor

    ok thanks for that - is a type K thermococuple (with clip on temepartrue sensor) suitable ? so when testing, if not open circuit, you need to watch the resistance reading doesn't go too low to prove it is faulty?
  10. S

    Testing a faulty Thermistor

    ok ! I know the resistance shoukd change with temperature change, wasn't sure though the best way to test - as some go faulty and not just on open circuit.. So basically - fire boiler up - turn off power, take temperature reading of pipe close to thermstor and check resistance reading.......
  11. S

    Testing a faulty Thermistor

    Yeah I know that - but what reading proves its faulty - as sometimes they only go fauly when the boiler is switched on! :D
  12. S

    Testing a faulty Thermistor

    Just a quicke - what's the best way to check for a faulty thermistor inside a boiler - as you have to check resistance with power off !!!...
  13. S

    vokera mynute error condition

    Does the pump have a permanent live connection to it..... new system wired up correctly? As with a pump overrun the wiring is slightly different Run the boiler - after about 5-10 mins turn the stat to off - see if the pump still continues to run
  14. S

    Potterton Kingfisher mf poroblems

    Is the air pressure switch working ?? is there power going to the aps?
  15. S

    Noisy Baxi 105 he instant

    the aav cap should be left loose - not fully tightened check your expansion vessel charge as this if flat can cause the aav to leak a little (scale around it)
  16. S

    Ravenheat RSF 82E wont go to main flame HELP !!!!!!!!!!!

    Check the flame rectification probe (flame sensor) is OK and it's lead. Also make sure the burner port is clean and that the flame is not bent.
  17. S

    Waste unblocking tools

    HappyPlumber - is this the ropump super? Or a different model? Where did you buy yours from?
  18. S

    Multimeter question

    Thanks JohnD for all of your help, I really appreciate it mate. I could do with one for measuring pipes/rads if in the future I get any probs. You just need to hold the probes down tightly I guess!!??
  19. S

    Multimeter question

    JohnD, could the Type K be put on a rad and test for cold spots or for testing the temp of a boiler flow pipe then?
  20. S

    Multimeter question

    JohnD, thanks for your help again :D So basically a type K isn;t for measuring thermocuples but for measuring temps!! So I plug the lead into the meter, touch a rad or pipe and it tells me the temp? Is that how it works? Holty - I am not gas safe registered, but just wanted to knw...