Search results

  1. V

    Good replacement for Baxi Solo 3 PF70?

    Thinking about replacing my Baxi Solo 3 PF70 and would like the modern equivalent in respect of Heat only and Output. Would appreciate views on the Worcester Bosch Greenstar Ri (27Kw) as such a replacement? Many thanks. Richard
  2. V

    Adjustment of a Bathroom Wash Basin

    Many thank Daniel and Rob, that looks to be a solution. Richard
  3. V

    Adjustment of a Bathroom Wash Basin

    Advice please? I have a Bathroom Wash Basin which slopes slightly forward. It sits on a pedestal - not sealed onto it via sealant - and is secured to the wall via normal screws, not Wash Basin fixings. My question - based on the pictures attached - is would I have enough adjustment by...
  4. Untitled

    Untitled

  5. Untitled

    Untitled

  6. Untitled

    Untitled

  7. Bathroom Basin

    Bathroom Basin

  8. V

    Heavy Wood Exterior Ornamental Shutters - Fixings to use?

    I have removed 2 1930s heavy wooden shutters (2.5' x 1.5'). They are non-functional/ornamental and were previously fixed between bricks via 4 wooden wedges (each shutter). I have since removed the wedges and now wish to re-attach the shutters to the front of my house using 4 (or 6)...
  9. V

    Best way to remove Stelrad Compact Top Grille & Side Pan

    I presume these can be removed for cleaning and then refitted? Would be grateful for advice on the best way to remove and then refit. Many thanks.
  10. V

    SHIRES Spares

    Called them this morning. Phone message states they're no longer trading, but if interested in purchasing stock to go to an online auction site. Wondered why I wasn't getting a response to my emails!
  11. V

    SHIRES Spares

    Also keen to find out where I can get Shires Adelphi spares online. Can't afford to replace existing system, but won't be getting another Shires! Thanks.
  12. V

    Extending current Lighting in Loft

    Thanks both once again, for clarification and very clear explanations. Regards. Richard
  13. V

    Extending current Lighting in Loft

    Thanks both. Think I understand. In other words, a Junction Box after the switch and then L, N & E to each Lamp Holder, so that one failed lamp won't affect the others? Cheers. Richard
  14. V

    Extending current Lighting in Loft

    I currently have a spur from my upstairs Lighting circuit (via junction Box) for a Switch and Light in loft. It's T&E into Switch (Live to Com / Earth to Earth / Neutral to Choc Bloc) and then Switch to one Lamp Holder (Live L1 to Live / Neutral Choc Block to Neutral / Earth to Earth)...
  15. V

    lining inside my roof

    I've got exactly the same problem, but am wary of covering the underside of the tiled roof with anything other than a fully permeable membrane. I intend to staple Weed Control Fabric to the underside soon. It's fully permeable, but not waterproof, that way I'll be able to see if my roof ever...
  16. V

    Baxi Solo 3 70 PF - Keeps going to overheat.

    It was the pump. Replaced and all has been well for over a week now. Many thanks for sound advice.
  17. V

    Baxi Solo 3 70 PF - Keeps going to overheat.

    Good advice. Many thanks. Will report back!
  18. V

    Baxi Solo 3 70 PF - Keeps going to overheat.

    Thanks. Will check out pump again tonight.
  19. V

    Baxi Solo 3 70 PF - Keeps going to overheat.

    1. Baxi Solo 3 70 PF Gas Boiler / Landis & Staefa RWB9 Time Clock / Switchmaster Motorised Valve / Grundfos Selectric Pump. 2. Boiler keeps going to Overheat. 3. Nothing done prior to overheat problem. 4. Started 4 weeks ago. Since then have put in Sludge Remover, then drained...
Back
Top