  1. J

    common problem?

    That's the cookie!! thanks I now have it wired as :- COMMON to terminal 4 ON to terminal 5 OFF is not connected this seems to be working fine now, thanks for all your help. J
  2. J

    common problem?

    I've connected 2 > 4 & 3 > 5 as you said but where do I connect the COMMON to the W/C? The room stat isn't operating the heating with just these two wires connected. thanks J
  3. J

    common problem?

    Thanks for your reply but I'm a little confused by that? The room stat is a battery powered digistat with the instructions shown in my 1st post. Where exactly do I wire the ON , OFF & Common wires into the wiring centre? thanks again :)
  4. J

    common problem?

    I'm replacing my useless and unreliable RF room stat with a wired one. I know which 2 terminals are call & satisfied in the wiring center but do I simply connect the COMMON to the live terminal in the wiring center? The "digistat" simply says in the manual 1 - COMMON 2 - ON 3 - OFF...
  5. J

    Problem with RF room stat (salus rt300rf)

    That's done the trick!! :D You're a star! thank you very much *** If I can help you some time, feel free to ask. I'm a precision engineer and web programmer if you ever need help in either field.. Cheers!
  6. J

    Problem with RF room stat (salus rt300rf)

    OK, I'll do that now.. I DO appreciate your time and help :D
  7. J

    Problem with RF room stat (salus rt300rf)

    OK, this is what I had done. with the LINK (on salus) still in place: Live from T1 to live on salus N from T2 to N on salus SL(ON) going to T5 and SL(OFF) going to T4
  8. J

    Problem with RF room stat (salus rt300rf)

    Looking at the SALUS manual, I wired it according to the 230V switching method and NOT the one below it, the volt free method! Should I wire it using the volt free method?
  9. J

    Problem with RF room stat (salus rt300rf)

    T4 (on junction block) is from terminal 3 on programmer T5 (on junction block) is white wire going to the MV OK, I'll re-write what I should have in the 1st place: Using terminal 2 for the common. PROGRAMMER SET TO OFF & STAT NOT CALLING: (T4)=240V - (T4) = 0V PROGRAMMER SET TO...
  10. J

    Problem with RF room stat (salus rt300rf)

    Sorry, yes I meant terminals 4 & 5. So You want me to remove the WHITE wire to see if the reading is still 156V right? I'll do that now.
  11. J

    Problem with RF room stat (salus rt300rf)

    If it helps you understand this any better, I've used the wiring diag on page 4 (top one) of the SALUS manual as linked in my original post. thanks
  12. J

    Problem with RF room stat (salus rt300rf)

    Thanks for your replies, this is readings I have taken: Using terminal 2 for the common. PROGRAMMER SET TO OFF & STAT NOT CALLING: (T3)=240V - (T4) = 0V PROGRAMMER SET TO CON & STAT NOT CALLING: (T3)=240V - (T4) =0V PROGRAMMER SET TO OFF & STAT IS CALLING: (T3)= 156V - (T4) = 240V...
  13. J

    Problem with RF room stat (salus rt300rf)

    Let me add some more info. As above, I've given the receiver power from terminals 1 & 2. Terminal 3 & 4 were linked together, I'm assuming this was to override the fact that there was no room stat? I have taken out the loop and put the ON & OFF wiress from receiver to these 2 terminals...
  14. J

    Problem with RF room stat (salus rt300rf)

    I have tapped the (L) & (N) to terminals 1 & 2 on the wiring block.
  15. J

    Problem with RF room stat (salus rt300rf)

    Hi. Is there anyone on here willing to help me with a small problem? What it is, I have recently moved to a new house with CH but there isn't a room stat to control the heat, only a programmer (ST699P). The heating system is a Baxi (back boiler) with the following wiring layout (minus the...