Search results

  1. D

    Installing external insulation on single skin wall in garage

    We have a single skin blockwork wall between our utility room and integral garage. I want to add insulation to the garage side of the wall to bring this up to Building Regs. From research the method of insulating externally is to bond PIR insulation to the wall, then add a mesh and finishing...
  2. D

    To cavity or not to cavity? New wall above solid wall

    The foundations and wall will be checked as part of the work (but highly likely not to be an issue). Cannot do external insulation as it has to match existing brick. My question is how to build up the wall to receive the cavity as that is what I would like to do. Any helpful suggestions from...
  3. D

    To cavity or not to cavity? New wall above solid wall

    I am planning an extension above my garage, gone through planning but now sorting BR approval. The garage wall is two skin (brick/block) but with no cavity. When I build above this what is the best option? I have been advised that I can achieve the required u value by installing a two skin wall...
  4. D

    Engineered I beam floor joists - costs

    All, I am about to embark on an extension and was looking at using engineered floor joists (such as Steico) instead of solid wooden joists due to ease of installation of services. Does anyone know of the kind of costs before I specify these joists and blow my budget! Looking to use 200mm deep...
  5. D

    faulty mcb -light circuit

    Thanks for all the replies, going to get a new breaker and fit that. If that doesnt solve the problem then diagnostics will have to start!
  6. D

    faulty mcb -light circuit

    And prey tell how did you solve the problem?
  7. D

    faulty mcb -light circuit

    Sorry, misunderstanding....sequence as follows: 1) Circuit worked fine, hadnt tripped 2) Circuit switched off at breaker to change light switch; 3) New light switch installed; 4) Breaker wont reset; 5) Refitted old switch; 6) Breaker still wont reset; 7) Waited an hour whilst doing...
  8. D

    faulty mcb -light circuit

    The switch was plastic as the old one, just new. The wires were both red and connected correctly. There was no trip before the switch was replaced and now the MCB has let me reset it (after an hours wait), the system has not tripped since. All lights on the ground floor have been used and it has...
  9. D

    faulty mcb -light circuit

    I have just replaced a light switch following decorating and the circuit breaker will not reset. The switch is correctly wired as i have checked. Even put the old switch back to check the new switch wasn't faulty. After about an hour of doing other things i returned to the problem and the mcb...
  10. D

    answered without picking up phone

    Thanks all. Couldnt find where the ring wire was shorting on the extension so resorted to fitting a new master socket on the extension and only using the two speech wires. Job done. There is a good website which explains the potential issues and investigating them...
  11. D

    answered without picking up phone

    We have a dial tone and you can make and recieve calls. Problem is the phone only rings once, no more. If the phone is plugged into the master socket it is fine.
  12. D

    answered without picking up phone

    Got a weird problem, the phone answers itself. It rings once or twice and without picking up the phone it is answered. It is ok at the master socket but the minute the extension socket is reconnected it happens again. Dont want to rip out the cable to replace it if i dont have to. any ideas
  13. D

    Installing PIR - Wiring location

    I am refurbishing part of the house and installing coving, the existing PIR wire comes down through the corner of the ceiling. When I install my coving this is going to be in the way. What is the best way to install a new PIR and where should the wiring be put? Can the new PIR be installed on...
  14. D

    Filling a wall duct

    Just had our gas fire removed and therefore the vent in the wall is redundant. What is the best way to fill the redundant duct? It is a cavity wall which has been filled so dont want to pull the duct out in case all the filling comes out (also it wouldnt budge when I tried). Doing the work from...
  15. D

    Telephone and Network Points - Metal or Plastic back boxes

    Thanks for that, had bought standard metal boxes as it is a brick wall they are being installed in, just had a scared thought about interference! Didnt want to install them and then have problems later. Metal boxes it is. Many thanks
  16. D

    Telephone and Network Points - Metal or Plastic back boxes

    I am about to install a telephone extension and LAN network module (separate boxes). These will be sunk into the wall, but should I use the standard metal back boxes or plastic ones to reduce any chance of interference? Would be interested in peoples thoughts. I have copied this post in the...
  17. D

    Telephone and Network Back boxes - Metal or plastic

    I am about to install a telephone extension and LAN network module (separate boxes). These will be sunk into the wall, but should I use the standard metal back boxes or plastic ones to reduce any chance of interference? Would be interested in peoples thoughts. I have copied this post in the...
  18. D

    Wooden frame behind an electric fire

    The front of the wooden frame will be plasterboarded and then there will be a backing panel, the sides of the wooden frame will not be covered but as long as the fire doesnt get warm it will be fine. Thanks for your help.
  19. D

    Wooden frame behind an electric fire

    I have an open fireplace which I am boarding over and installing an inset electric fire and fireplace. There is a recess one brick deep around the area where the new fire will sit. Is it acceptable to fill this with a wooden frame to bring the front face level with the other brickwork prior to...
  20. D

    Noggins or Herringbone struts

    That was my initial thought, thanks for the replies.
Back
Top