  1. T

    I have come across a worcester 24i boiler,the problem is the time clock does not keep the...

    I have come across a worcester 24i boiler,the problem is the time clock does not keep the time,it does not move.When you have the clock set to manual or auto nothing happens on the central heating.When you turn hot water on the boiler kicks in,gives you hot water and if the central heating is...
  2. T

    back boilers

    to whitespirit 66, i was not aiming to criticise the guys work, i did not properly identifie the system, thanks for your time and help.
  3. T

    back boilers

    one more last thing before i go to bed, can i use fx100/fx400 in the system? if so i think you would have to put them in by the rads is this right or not? good night all.
  4. T

    back boilers

    one last thing before i go to bed,is it the norm to run a primatic with a gas fire/back boiler? good night all sleep tight
  5. T

    back boilers

    thanks for all your replies i did think it was a primatic after reading my jtl book but what should i do with the two gate valves? The women tells me she as used the plumber for the last 30 years should i let her know he is not super man like she thinks?If i now change the valves should i get...
  6. T

    back boilers

    I do a few jobs for a decorator i know, i take the rads off the wall when he wants to get to the back of them,and when done i come back.The problem i have is this last job i need to take the rads and change the valves as well but its a back boiler and i cannot found the F&E tank.I can turn the...
  7. T

    plumbing ravenheat combi boilers

    thanks for that alert .can you tell me whey the hot water is okay down stairs but not up?
  8. T

    plumbing ravenheat combi boilers

    thanks for that,now is the diaphragm and the diverter value all in that brass body in the centre of the boiler? all the primary and the hot waterpipe(10mm pipe) run into it. terry
  9. T

    plumbing ravenheat combi boilers

    I have a problem with a ravenheat combi boiler,no manul and i can not get to the badge.The central heating is fine,the hot warter down stairs is good but the upstairs hot water runs hot when first turned on then goes cool and then cold.The boiler runs for about 30 to 40sec and then turns off for...
  10. T

    heatline condensing boilers

    just to let you know that boiler i went to look at for my mate it had a split control knob for the central heating,got a new knob for the central heating and every thing is great,i told him it was very hard to fix and i got a few pints off him
  11. T

    heatline condensing boilers

    My friend as a heatline 24/28 condensing boiler.At the moment he as hot water but no central heating,he seems to think its the diverter vale,how do you check the diverter value is working? could it be the sensor on the primary flow?He also says he as a leak some where,he does not think its on...
  12. T

    glow-worm boiler fuel saver mark 2

    I have been told over the phone that her boiler,glow-worm fuel saver mark 2 is not firing up when the time clock(randall ndall 702) is asking for heating or hot water.The poilet light is lit ,the lights on the time clock all come on when she as asked the boiler to do something,hot water on...
  13. T

    rads not getting hot in new extensions

    if i turn off all the other rads apart from the problem two rads they get hot but as soon as i turn one of the up stairs rads on they start to lose heat.I have balance them and i left the job with all the rads being hot apart from the problem two rads which were warm but it was the best they...
  14. T

    rads not getting hot in new extensions

    the central heating system is a powermax 155x.sealed unit. when running the rads are red hot in the home.the pressure holds at 1.5 bar,no problem.But since they have had a single storey extension done the two rads in the extension(0.900x0.600) got hot when first turned on by the plumber and then...
  15. T

    one pipe centrel heating systems

    Hi all, first of all the job is in a pub, a very old one .all the central heating system is run on the one pipe system blue band steel pipe.the rads are the old cast iron ones.The boiler is a new one and is in the celler.there is a 22mm pipe run from the boiler of no more then 1mt to the 2"...
  16. T

    one pipe centrel heating systems

    Hi all, I am doing some work in an old property.The owners after having a extension put up and knocked down an wall now have an 2" pipe running across the opening.It is part of the central heating system an one pipe system.I would like to know if i can drop the pipe dia down to 22mm copper and...
  17. T

    baxi compi 80 eco boilers

    Hi all, Could some one please tell me where is the re set button on the baxi eco 80 boiler?My son as no hot water or centrel heating .The boiler will not light up and i have been told it could be the re set button or the circit board may need re placing. thanks, terry.
  18. T

    noisy central heating pipes, very noisey last thing at night

    thanks for your reply bengasman but what is crud? do you mean **** in the system if so could i flush it out and them but some solution in to help it run?
  19. T

    noisy central heating pipes, very noisey last thing at night

    its a very loud banging noise, the boiler is a worstchester donot know the type, will be calling over on thursday. the primary feed and return pipes going into the cylinder do seem a little wobbly and un-suported.there is also nno insurlation on the pipe work around the cylinder.
  20. T

    noisy central heating pipes, very noisey last thing at night

    my friend as noisy central heating pipes,they are at their noiseyest last thing at night but it does happen in the day but it does not seem as loud.