Search results

  1. A

    Salamander pump fault lights

    Thanks for reply All sorted Complete an air test! Follow these instructions to remove air from your pump installation. 1. Turn off pump. 2. Remove shower head from hose. 3. Let hose hang into bath or shower tray. 4. Turn the temperature to full cold. 5. Turn the shower on and run for 5...
  2. A

    Salamander pump fault lights

    So have these fault lights on my pump and was working great for years but now this has happened? Is there a fix for this I can do or is it a dead pump many thanks
  3. A

    Nest 2nd gen goes orange on app but does not turn boiler on

    Nest 2nd gen goes orange on app as to say it’s on but does not turn boiler on, so nest connects to the base wireless fine and to the app on phone fine press on on the phone and it turns orange to say it’s on but the boiler does not click on This has just started happening and was working fine...
  4. A

    Baxi Solo he 24 red fault light

    just fitted a new electrode kit and the boiler fired up and worked but then noticed it was melting the ceramic wire/casing ? so for some reason its over heating the wire has anyone come across this problem
  5. A

    Baxi Solo he 24 red fault light

    Hi My Baxi fires up for about 2 secs then goes off does this about 5 times and then the red fault light comes on so then have to reset but sometimes takes 6 attempts to stay Light sequence red off green I think this ignition lockout I cleaned the condensate bit and also took the the cover...
  6. A

    baxi solo he A 24 HEAT EXCHANGER

    Had no leaks since i have had it except this core plug, and yes it took me ages to swap out but now i have another heat exchanger now that is fully working as thre core plug just slots back in! So if anyone interested?
  7. A

    baxi solo he A 24 HEAT EXCHANGER

    Wish i knew that before i bought another one!! Ok thanks for your help
  8. A

    baxi solo he A 24 HEAT EXCHANGER

    so what you are saying if i can knock this core plug back in so its flush like the others then its good to go? Also what would of caused this core plug to pop out?
  9. A

    baxi solo he A 24 HEAT EXCHANGER

    Hi I have just swapped this Baxi solo he A 24 HEAT EXCHANGER over as there was water coming out of the side i am not a boiler engineer but i was wondering as theres nothing wrong with the exchanger just this cap thing popped out the side is there a way of fixing it or is it shot?
  10. A

    Draining the radiator system.....How to?

    Draining the radiator system.....I have this system in the garage and if i screw the red button at the top above the gauge it drains water outside do i need to anything else like switch the mains off? o?
  11. A

    Vita spa hot tub power then no power

    Not the answer!!!
  12. A

    Vita spa hot tub power then no power

    I think I have found the fault once the filter cycle starts it should only use jet 1 but a few minutes into the cycle it starts jet 2 as well and the cycle goes for 2 hrs at a time so I think it’s overheating and switching off but I can just press jet 2 off and it runs fine! So wondering if...
  13. A

    Vita spa hot tub power then no power

    Ok checked all connections inside and out all seem fine?!
  14. A

    Vita spa hot tub power then no power

    Ok I will check them
  15. A

    Vita spa hot tub power then no power

    Pretty much yes!! Happened when the hot weather came Is there anything that can be done!
  16. A

    Vita spa hot tub power then no power

    Yes but there’s no power even now just checked so I can’t turn it on just comes on on it’s own?
  17. A

    Vita spa hot tub power then no power

    What does that mean
  18. A

    Vita spa hot tub power then no power

    I have a vita spa hot tub been working fine but sometimes when I open the lid there is no power , press the buttons on control panel and nothing! Then come back to it later and it’s running through it’s cycle and working fine all pumps,jets,heater everything works Checked all breakers and...
Back