Search results

  1. S

    Remeha avanta plus 28c noisy

    Gas valves dont kettle noise, The guy said its more or less kettling and believe me i have been to alot of duo-tec and remeha that make kettling noises when getting upto temperature with muck in system, yes it maybe gas valve as well though ,like i said hard to tell not being on site,only trying...
  2. S

    Remeha avanta plus 28c noisy

    No air is different noise anyway, Get some good sentinal or fernox cleaner and leave in a couple of week, drain and leave then after a couple of days do it again, no easy fix but it will be better,cant think of any other reason ,noise is hard to diagnose you need to hear it, hope that helps ta...
  3. S

    Baxi 105e Leaking Diverter Valve Assembly

    Probably sensing pipe ,,advise retighten then check, never used any ptfe tape on em,they have never needed it.
  4. S

    Remeha avanta plus 28c noisy

    Advise get the C/H system cleaned, probably muck in the heat ex.
  5. S

    Baxi Bahama 100 - 3 way divertor valve cartridge

    Touch something and it effects everything else :oops:
  6. S

    Baxi Bahama 100 - 3 way divertor valve cartridge

    One point about this boiler, is does not like to be messed with, so what may look like a tiny leak will turn out to be something of a minefield once you start opening it up, not for the faint hearted but a good learning curve if you want to have a go.
  7. S

    Remeha has rejected my warranty

    Thing is nowadays, customers and installers(me included) want top spec products at rock bottom prices,it aint going to happen.
  8. S

    Remeha has rejected my warranty

    Now that everyones got off :!: :!: on calling heateam, One engineers fault findings .Without a person being on site you cannot surely comment fully accurate findings, so totally slagging off engineers and organisations is bang out of order, and not required in any forum. Been to and worked on...
  9. S

    V Noisy Baxi Solo 24HE Bolier

    Probably sludge in heat exchanger, get yourself a bottle of cleaner.
  10. S

    Potterton Promax 24HE keeps eating door seals

    Ok buddy, Still here ,,, :D , summer on its way ya know what i mean :D
  11. S

    Potterton Promax 24HE keeps eating door seals

    Tell you something though ,,They all break down sooner or later, no matter what manufacturer. Still keeps us in work :)
  12. S

    Potterton Promax 24HE keeps eating door seals

    new burner and or heat exchanger sump required. gas installer required.
  13. S

    Baxi Combi Instant 105e - Faulty diverter valve motor?

    Seen this fault numerous times, no short cuts, and never had it yet where only motor faulty, parts required are diverter valve complete, check and or fit expansion vessel whilst boiler drained,you will find air required in vessel,,,,,and no not a nice job to do and have plenty of washers at hand,
  14. S

    Potterton Power Max 155X

    plate heat exchangers are still available,
  15. S

    Potterton Promax 15HE not modulating

    Sounds a bit strange,,,, who is newteam , did you check to see his gas safe card.
  16. S

    Potterton Promax 15HE not modulating

    A RGI is required to carry out this work.
  17. S

    Potterton Promax 15HE not modulating

    Gas valve not adjustable, modulates from pcb, I would check standing and working pressures.
  18. S

    Baxi 105e Probs

    pump proven switch not making,, pump or diverter fault, worn .
  19. S

    baxi combi installing a digital timer

    yes , 1 black wire to 3 and 1 to 4,
Back