  1. B

    Sulphate test. Type 2 result.

    We've recently had a sulphate test done on my mums house. It resulted in type 2. Do we have to get it done? Or will a mortgage provider provide a mortgage on this type of result
  2. B

    Salamander pump pulsing

    Hi Ken, It does happen on both pumps, and when it happens it happens on both pumps. Like this morning, my wife had a shower this morning, and I (after playing golf) wanted a shower but it just started pulsing. I left it for about 10-15mins, and then it started fine. Yesterday we had showers in...
  3. B

    Salamander pump pulsing

    My salamander pump (RSP100 2 bar pump) supporting 2 showers, works most times, but then once it has been used, and switched off, will not work again, starts pulsing, for another 15-30mins. But this is not alsways the case. it will usually come on again in the evening, or the following morning...
  4. B

    Salamander power pump problems

    and I have a 100 gallon cold water tank. We all used to shower at one time, (4 of us, on school days).
  5. B

    Salamander power pump problems

    oh and by the way, it is a 3 bar pump that could serve two showers, (but we only use one at a time, kids have left home years ago).
  6. B

    Salamander power pump problems

    We have hot water after every shower, but I can hear the CW tank filling up, while it starts to hunt, thats whyI wondered if the CW head being too low will make a difference. if I put a second Ball cock in, will it make the tank fill quicker, or do i have to put somethink like a mini pressure...
  7. B

    Salamander power pump problems

    I may have been quicker when I shower than I actually am, and usually the missus goes in first and she must be in for about 10 mins at least. If it is draining the water what could do about it?
  8. B

    Salamander power pump problems

    It gets warm after the 1st shower, but We cant usually get a shower for 20 mins after we have stopped the first, usually use it for about 2-5 mins.
  9. B

    Salamander power pump problems

    The pump does become hotter, but you can touch it but its not uncomfortable
  10. B

    Salamander power pump problems

    Ok i'll try that tomorrow.
  11. B

    Salamander power pump problems

    Has anyone had a problems with a Salamander power shower pump. Mine will not do 2 showers one after the other. The first is OK, but the second one starts hunting, and will not pump correctly, after a while, about 20mins, it will start again, shower OK, but again wont work straight after. It...
  12. B

    possible T valve problems???

    Put new valve in works fine, only thing is that it cuts the CH off when the HW tank reaches a certain temp. I don't think this should happen, do you think it was wired correctly as I have swapped the. Wires colour for colour. And the valve is the same way around.
  13. B

    possible T valve problems???

    I've yet to do it Will try to do it this weekend. Only thing I don't fancy draining the whole system.
  14. B

    possible T valve problems???

    Still didn't work so I brought a new valve.
  15. B

    possible T valve problems???

    thanks I'll try tha.
  16. B

    possible T valve problems???

    yes thats the one D_Hailsham and its been working for the 25 years Ive lived here STEM
  17. B

    possible T valve problems???

    It manifests as follows: - The central timer comes on. - The Water only gets hot. - All the CH rads all stay cold. - I go and turn the manual valve on the T valve the CH comes on. - and it is fine until the CH timer goes off. And the same happens again. If i leave it the HW thermostat on...
  18. B

    possible T valve problems???

    Yes there's 240v on the motorised valve
Back