  1. A

    Baxi Solo 2 40pf fires up only from 3rd time

    thank you for the prompt response is it better to call a big company like BrGas or find local Gas Certified Engineer. Are you allowed to give recommendations on whom to use? Also how big is this problem and how long till the boiler stops working? just a matter of interest
  2. A

    Baxi Solo 2 40pf fires up only from 3rd time

    Dear All my boiler seems to have problem firing up from the first time each time it has to try 3 times before starting normally what would this be? Ignition electrode? (it is about 13 years old i guess)
  3. A

    baxi 2 40 pilot light on fan on main burner doesnt ignite!

    Well, new solenoid has the same resistance 1.5kOhm, which indicates that my diagnosis is wrong(or rather manual has wrong details) anybody could share a manual for this boiler, maybe? I would appreciate it very much as the quality of mine is not v good. I take to fix it I would need new...
  4. A

    baxi 2 40 pilot light on fan on main burner doesnt ignite!

    its a known problem on these that the solenoid fails on the gas valve, it can be changed as a seperate part 2 wires and a clip to hold it on. if it isn't then its likely to be a pcb i'm afraid Thank you for your post. PCB was changed few months ago so i doubt it is that and the rest of...
  5. A

    baxi 2 40 pilot light on fan on main burner doesnt ignite!

    the flame is alight. Found out that resistance on gas valve solenoid is 1.5 kOhm instead of 5 kOhm. Suppose replacing that should fix the problem, am i correct in thinking that?
  6. A

    baxi 2 40 pilot light on fan on main burner doesnt ignite!

    it makes the usual noise and water is pumping where would i look? thank you
  7. A

    baxi solo 2 40 sparks from regulator/c-board on the boiler..

    thank you everyone all sorted - board swap worked well nice and worm again! :lol:
  8. A

    baxi solo 2 40 sparks from regulator/c-board on the boiler..

    sounds like a boiler replacement to me as this one is 12 years old could you please tell me which boiler model would fit without alterations in the system? i would love to take one out and put new in (not me personally of course) thank you!
  9. A

    baxi solo 2 40 sparks from regulator/c-board on the boiler..

    what about the noise though? would the fan or pump fail in this case?
  10. A

    baxi solo 2 40 sparks from regulator/c-board on the boiler..

    strange issue.. We have been away for a week, came back today and put the heating and h/water on. (The heating was on while we were away 2 times a day controlled at 16 degrees by the thermostat on the wall supposedly) I was out and my wife rang me to say that something started smelling of...
  11. A

    Hot water only electric???

    oops! of course it is on - i have hot water ok, thoug it seems my thermostat is not happy as i get very hot water and reducing temperature doesnt really help by the way if i switch immersion heaters off (can i do that?) would the gas kick in?
  12. A

    Hot water only electric???

    just to say, obviously if i understood you correctly, heating is working fine and hot water is also fine, but hot water only heats up by electric heater, gas is only used for central heating so far. i feel that gas should be used for both and electric should kick in only if necessary or am...
  13. A

    Hot water only electric???

    how would i check?
  14. A

    Hot water only electric???

    Hi everyone, I am new to this topic and have a silly question the house is about 12 years old and I have a baxi solo 2 40pf boiler in the kitchen and a hot water cylinder upstairs. It is controlled by honeywell timer thing. It seems to me that the gas boiler only works for central...