Search results

  1. S

    What Boiler Should I Get.....

    And how do you think the regulation change will effect anything, most people including a lot of installers ignore Benchmark now, so just saying that the CO ppm must be noted in the Benchmark will not change anything, until manufacturers start invalidating boiler warranties if the boiler has not...
  2. S

    Designing a new hw/ch system

    Why on earth would you install two boilers, there is no need
  3. S

    compression fittings on gas pipe under floor

    Just thought I would point out, Gas Safe don't make the regulations, so calling them Gas Safe Regs is incorrect
  4. S

    Confusing problems with heating system

    Not far, we may be able to help
  5. S

    Gas Safe required?

    Just going by the first post, they said that they can fit a new supply, nothing mentioned about the cooker, they do need to be Gas Safe registered to do the pipework, but only need CCN1 for for the pipe. Just saying, don't want to get into a long, drawn out boring debate about it though :)
  6. S

    Confusing problems with heating system

    The powerflushing is probably clearing the muck at that time, but by just sticking raw water in and a cocktail of chemicals is obviously causing more corrosion to occur again, you need to have the system water checked properly, pH, conductivity, salts etc, this will then identify what the...
  7. S

    Gas Safe required?

    Why would they need CKR1 just to run a gas supply, CCN1 is sufficient just for the pipework
  8. S

    Power flushing kit

    Self education, I look to Europe for the answers, I have test equipment that lets me test pH, TDS, Salts and conductivity all from one unit, installers need to arm themselves with such equipment, if they want to avoid warranty refusals based on water quality
  9. S

    Boiler "Immediately Dangerous" on flue external CO

    The new regulation brought in will allow up to 350ppm Total nonsense if you ask me, most boilers I commission when set to manufacturers CO2/O2 settings I get around 30ppm
  10. S

    Power flushing kit

    The industry is spoon fed drivel by the chemical companies, it is not to improve heating systems, its driven by profit, powerflushing, inhibitors, its all nonsense, why inhibit a sealed heating system, oxygen has to be present for corrosion to occur, installers need to ensure de-gassing is done...
  11. S

    Power flushing kit

    Flushing yes, but Powerflushing is the gimmick
  12. S

    Illegal gas installer prosecuted !

    Are you having a laugh, what has the colour of the van they use got to do with them been illegal boiler installers, what a stupid thing to say
  13. S

    Power flushing kit

    Power Flushing, another unnecessary gimmick that is not required
  14. S

    Fitting system filter before cleaning/flushing

    It does amuse me how lots of the public and installers think filters are a problem solver, they are not, they merely mask the problem, if you have corrosion in your system, solve the problem, don't mask it, a well installed system will not suffer from corrosion, I have been to many open vented...
  15. S

    Which Combi Boiler??

    Dan_Robinson has answered your original question and gave you a list of his preferred combi boilers, but this list would change with each installer who answers, there is no definitive answer to your question, each installer has their own preference, so ask the installer you will use for his...
  16. S

    Viessmann Vitodens 100 system boilers

    As most systems, it is hot water priority
  17. S

    solar geyser "sucks" air

    Contact http://www.genersys.co.za/ ask to speak to Mike Leighton, they install thermal,solar systems in South Africa and I am sure will be able to assist with your problem
  18. S

    Geminox Megalithe 30S central heating pump

    The Bosch Group own Geminox boilers, that is why the pump is marked Wilo Bosch Tony
  19. S

    Connecting Gas appliances

    mobile gas units such as gas fires are flueless, they also come with the hoses supplied which would of been tested at the factory, the gas bottle is contained within the unit which was made and tested at the factory as a complete working unit, the hose has simple bayonet connections for...
  20. S

    Is this work acceptable (pics)? Central heating system.

    it is fine having plastic pipes in the screed without joints and without conduit, but as you rightly say UFH is done that way, But UFH pipes have 65 - 70mm of screed on top, I doubt the pipes in the pictures will have that much coverage, so he will risk cracking of the screed, as for joints in...