  1. B

    new plumber after some help please

    you need to check in loft space for header tanks, as pipes may go up within studwork. Best course is to redesign sytem to customers requirements.
  2. B

    Chrome Pipe question

    you can't solder chrome pipe, you can't use push fit. all you can use is compression fit, but it's advisable to rough up the pipe with a bit of emery first.
  3. B

    Vokera 24-96 Flowmatic

    no activity for a while, does this mean you guys haven't a clue, or is it too difficult even for you all. (i've asked for help from vokera, but seeing as they only sell the stuff, they don't want to reply).
  4. B

    Potterton Puma 100e not firing up

    try checking air pressure switch and tubes going to it, sometimes you get a crack in the tube, which will stop boiler firing.
  5. B

    Vokera 24-96 Flowmatic

    When the faulty pump was replaced, it didn't fire up and there was a voltage across pins 10 & 30, which according to the vokera flow chart said replace pcb. once pcb replaced it did fire but not circulate round primary cct. wether it was the pump that blew it or something else i don't know.
  6. B

    Vokera 24-96 Flowmatic

    thanks for speedy feedback, picasso. yes we've done all you've mentioned. when filling system, we also bled boiler of air via nipple. have checked overheat stat and it's not popped out. flow and return valves also definately open, and pressure at 1.5bar. got nasty feeeling it's blowing pcb, but...
  7. B

    Vokera 24-96 Flowmatic

    This boiler stopped working, kept tripping mcb, turned out pump fault, replaced pump and pcb, cured that problem, but now hot water ok, but rads not heating up. Boiler was firing up and flow leg was heating up, but return stayed cold, changed diaphragm in heating manifold. now back to start and...