Search results

  1. S

    Under counter Water heater ID

    Can anyone identify this water heater. Thanks
  2. S

    shower valve id

    can anybody ID this valve for me as it needs a new cartridge Thanks Its the chrome one with the riser attached
  3. Untitled

    Untitled

  4. S

    Shower identification

    Can anybody tell me what type of shower this is as i need a new cartridge. Tim
  5. can you identify this shower

    can you identify this shower

  6. shower

    shower

  7. S

    Air admittance valve

    I have a customer with an internal toilet fitted to a 1.5m SVP with an air admittance valve on top ,the push on type with a rubber boot and not solvent welded. The trouble is the pan keeps backing up but when i remove the rubber boot or the valve the pan clears . Is there anything on the...
  8. S

    Screed over heat mat prior to tiling

    I have a impey wetroom tray and need to lay my heat mat over the floor including the wetroom tray..I then intend tiling it with mosaics. I need to cover the heat mat prior to tiling obtaining a flat surface. As i cant use self leveling because it will run down the tray,can anyone suggest a...
  9. S

    Unvented direct cylinder

    Just fitted new cylinder heating up ok but the hot tap is very powerfull and eratic 3.5 bar coming in to house 3 bar prv on side of tank 3 bar expansion vessel any suggestions welcome
  10. S

    Shower Pump

    THANKS EVERYONE FOR YOUR INPUT I FITTED A CHECK VALVE BETWEEN THE S FLANGE AND THE PUMP ON THE HOT SIDE AND THAT FIXED THE PROBLEM. TIM
  11. S

    Shower Pump

    w/machine does have 2 hoses and if i fit check valves will that not inhibit the flow to the pump. Tim
  12. S

    Shower Pump

    Thanks Dan The other hot taps dont start the pump its just the thud of the w/machine demand that starts it, and the flexi,s with iso,s are fitted but a check valve was not supplied in the kit Salamander RSP50 Tim
  13. S

    Shower Pump

    The hot does have a dedicated supply from the S flange
  14. S

    Shower Pump

    I have installed a shower pump with a Surrey Flange for the hot and a dedicated supply for the cold and it works fine ,but when the washing machine calls for hot water the pump starts. Could you give possible reasons and solutions for this problem. Thanks Tim
  15. S

    1200 x 600 shower tray

    Is there such a thing as a customer of mine has limited space Thanks Tim
  16. S

    Halstead Ace High no DHW

    thanks kev bit tight changing the diaphram but worked fine on completion thanks for your help. tim :lol:
  17. S

    essex flange

    how hard is it to fit an essex flange with a 22mm draw off. what size hole saws are required and how to deal with the insulation on the tank thanks tim
  18. S

    Bathroom walls

    not if you run a traffic
  19. S

    Bathroom walls

    sounds to me you need to dot and dab .Plaster board adhesive in 6 lge bads on a 6x3 sheet then stick it to the brick wall level as you go and tile next day on a flat wall.
  20. S

    Halstead Ace High no DHW

    thanks Kev is the diaphram inside the group set tim
Back
Top