Search results

  1. A

    Weather Compensator - Vaillant VRC 430 setup

    I've had a VRC 430 for a number of years but only really just getting round to configuring it correctly now that the missus is nagging me about the cold upstairs and the kids waking up in the night Currently its mounted into the wall in the living room and set to Thermostat mode with a curve of...
  2. A

    Building over a surface drain

    Any advice on capping a surface drain prior to laying an oversite for a conservatory I have two drains to the rear of the property both are gully types with a grid and collect rainwater and currently have feeds entering them from the bathroom and kitchen waste these feeds are being moved...
  3. A

    Conservatory oversite plans

    Hi All, I just came up the following spec for the oversite of my 6x3m conservatory I'm looking to install a wet heating system with a 65mm thermal screed before tiling / laminating Does it look spot on or am i being too cautious with the thickness of the insulation and multiple vapor...
  4. A

    Conservatory Footings

    Hi all, I've Just had 600x600 footings dug for a conservatory cavity dwarf wall sat on clay at the rear of my property Due to the removal of part of concrete slabs what used to be my patio some of the trench walls have collapsed, should i just clear them out and pour the footings or add...
  5. A

    Gardening terrace with sleeper retainers, will this suffice?

    I'm currently in the process of terracing my garden into 3 raised terraced levels, the height of each level is between 600-900mm and the soil is a mix of clay, well wet clay this time of year My plan is to use 100x200x2400 softwood sleepers as retaining walls for each level by arranging the...
  6. A

    Summerhouse Base overkill?

    Hi All, I'm in the process of digging out a 7.5m x 4.3m (32m2) plot to stand a concrete base for a summerhouse, the overall depth of the plot varies slightly from 150-250mm from where the garden slops in both directions My plans are to make use of the piles of general hardcore and rubble i...
  7. A

    Premier 24 Zone issue?

    Hi Guys, just wired in a Texecom Premier 24 panel with no expansion cards so just the 8 zones made up from 3 PIRs and 2 Contacts i have used EOL on all the wiring Zone 1 on the keypad is mapped to Zone 1 on the panel the remaining 3 panel zones are set to "not used" as detailed on page...
  8. A

    Ecotech Plus 831 Combi with VRC430 + VR81

    Hi Guys, Hope one of you gurus with extended knowledge on heating systems can clear something up for me Just had a Valliant Ecotect Plus 831 installed with the standard TimeSwitch 130 thats the 24h analog timer which we tend to leave on timer 7pm - 11pm for the central heating, all rads...