Search results

  1. J

    Galaxy Alarm "High Res" Event

    Thanks Guys, Replaced the sensor - the new one has connectors which are easier. I have screwed it on and it sits on 1000 ohm resistance but occasionally pops up to 1005. (1994 when open), but I did notice just once it go to 994 and then back up again. It has not seemed to do that again...
  2. J

    Galaxy Alarm "High Res" Event

    Thanks, I opened the sensor and it's basically taped to resistors and the connector. I rewired it properly rather than linking to the old cable. It seemed ok on a quick test and tamper checked fine. I will try the resistance check from the panel tonight (did not know you could do that)...
  3. J

    Galaxy Alarm "High Res" Event

    Hi, Rewired some bits on my Galaxy alarm and it all seemed okay, but now, we occasionally get an event when armed. The log says "High Res" on a door contact, but no other information. What does this mean and is there an easy was to solve it? Tony
  4. J

    Galaxy 8 bell triggers on set

    All sorted - another person on a different forum spotted the problem. The bells were configured as 'set' because the bell unit was not wired into the default terminal as per standards. I have the manuals and whilst it was a pro install, it's my alarm and my house so I can play with it if I...
  5. J

    Galaxy 8 bell triggers on set

    Thanks Europlex, the loss of memory was possibly due to the time the power was disconnected during some building work. I will source a new battery. Do you have any idea why the bell rings when the system is set. This is my only real problem now. Thanks Tony
  6. J

    Galaxy 8 bell triggers on set

    After a prolonged loss of power and some replaced PIRs my Galaxy 8 alarm had lost it's memory. I have reprogrammed it, and the walk test and tamper test all work great. But... when I set the alarm as soon as the 'system set' message appears, the outside box bell rings. There are no...