    vokera linea 24 dhw luke warm

    Oh you mean the one where the pcb stops the gas valve going full rate and never gets above 42 degrees due to eec European stuff or something where pcb's are made. British gas software also confirms this is the case !! Besides its fixed now n'all
  2. R

    vokera linea 24 dhw luke warm

    Oh it was the PCB in anti scald mode BTW :D forget to respond sometimes sorry
  3. R

    vokera linea 24 dhw luke warm

    oops should have posted in combustion chamber sorry.
  4. R

    vokera linea 24 dhw luke warm

    gas pressures champion etc. Forgot to mention this is a downstairs flat. An identical system in every way is in the upstairs flat. At the same out let but in the flat upstairs the boiler will read 58 degrees and the hot water is too hot to keep your hand under too long. I services...
  5. R

    vokera linea 24 dhw luke warm

    Hello been a while. Got a vokera linea just lukewarm hot. Dhw temp on boiler display reads 42 degrees and no more at 10 lites per min. When you close hot tap temp on display reads 58 degrees. Pipes to diverter manifold are very hot. Diverter overhaul kit has been used but no difference. Any...
  6. R

    Help please. CCTV setup. Long garden. Night time.

    my fist's have already sorted that problem.
  7. R

    Help please. CCTV setup. Long garden. Night time.

    Hi, I require a CCTV security system that will give me good clarity if poss, mainly night time and a bit day use. I have a long garden out the front (30-40 mtrs) and a small back yard where i keep my van on a night. Its a rough neighbourhood, gates get kicked in and usual stuff...
  8. R

    MIRA ADVANCE ATL no power no red light

    What about the one shot trip ?
  9. R

    MIRA ADVANCE ATL no power no red light

    Hi, Anyone handy with the older version of the mira advance atl 8.7kw shower ? I have 240v at the terminals on shower and no red led light is on? shower is dead. Mira have advised they cant help me other than get their engineers out at 150ish quid. I know there is a pcb, relay...
  10. R

    Baxi 105e hot water only 50 degrees???

    Yes I see what you mean but this boiler is old and used to work fine in the past. Or so they have led me to believe. They keep saying it fine when CH is on? Mabey its me listening to them too much and the boiler is fine. Thanks for the help from everyone .
  11. R

    Baxi 105e hot water only 50 degrees???

    oops should read when incoming cold water becomes cooler
  12. R

    Baxi 105e hot water only 50 degrees???

    so it isnt true that when set to max temp this boiler will reach 65 degrees or more ? I was thinking after my initial test over 1 minute, the correct temperature rise was acheived, but the temperature will not go up any further even when on max setting after a prolonged period. petit_pablo...
  13. R

    Baxi 105e hot water only 50 degrees???

    sorry my previous post not too clear. even after 30 mins the hot water would still be 51/52 degrees
  14. R

    Baxi 105e hot water only 50 degrees???

    incoming cold temp 17 deg ! Temperature rose to no more than 51/52 degrees with a flow rate of more than 12ltr/min. Lady now thinks her hot water is fine. burner pressure is at 12.5, g4 meter gas rate 3.23 I noticed at one point the boiler temp guage read 80deg plus and the pump was...
  15. R

    Baxi 105e hot water only 50 degrees???

    Because im still learning and didnt write them down. :oops: New I should have kept my mouth shut till later
  16. R

    Baxi 105e hot water only 50 degrees???

    :roll: no I didnt check the thermistor because visually it was covered in thick white powdery residue and rust all over the thermistor (looked like it had been leaking from there). I felt sure it was this, but realise it would have been better to check its resistance when heat is applied to...
  17. R

    Baxi 105e hot water only 50 degrees???

    Hi all, Got a customer with a baxi 105e. CH is fine. DHW the temperature is only luke warm. Thermistor just changed. Tried cleaning the heat exchanger with a lime scale remover overnight. Flow rate seems ok. Diagphram 1yr old. Any suggestions as to what it is? The DHW heat...
  18. R

    Motorised valve problem

    Thanks guys it was a stiff knackered valve (bit like everything else on this system!) Replaced with new after following advice. Cheers
  19. R

    Motorised valve problem

    Hi all first post here, hope you guys can help. Got an ideal classic system boiler which has had a new pump installed. After getting rid of the usual air locks, the water going into the cylinder via the flow and return pipes is now hot. I can only get hot water when the heating is on...