    Hotpoint Aquarius WDL540G - 4 lights flash at the bottom

    hi Rock1 thanks for your help. I checked the system and found a damaged wire to the thermistor. repaired and working fine.
  2. R

    Hotpoint Aquarius WDL540G - 4 lights flash at the bottom

    I shall give that a go. thank you.
  3. R

    Hotpoint Aquarius WDL540G - 4 lights flash at the bottom

    Hi all I hope someone can help. I have a Hotpoint Aquarius WDL540g washer/dryer. It has been working fine, but recently It developed a fault. The 4 Bottom lights were flashing fast, whilst there was water in the drum. I pulled the green cord for manual open, and the pump started running...
  4. R

    Hotpoint - wdl540g - drain pump runs for 3 seconds only

    Hi Rock much appreciated with your prompt reply. did some further investigation, found that the probe is in working order, and also found that the cable to the probe had snapped due to the heat from the dryer. I shall be repairing that, and I am 99.9% sure it will sort the problem...
  5. R

    Hotpoint - wdl540g - drain pump runs for 3 seconds only

    Hi all i hope someone can help. i have a wdl540g hotpoint washer dryer. it has been been fine for 4 years, and now i have problem. the system does it cycle, but is to the system to drain, the pump works for only 3 seconds or so. i have checked the following, the Main...
  6. R

    Heating suddenly stopped working.

    the system was working fine, what had happen was i installed a new pump, and after powering up, 30seconds later, the pump stopped and boiler stopped i have a remote wireless stat which had a low batt hence it would not call for heat and there for it wouldnt fire up. replaced batteries and...
  7. R

    Heating suddenly stopped working.

    Thank you Armo74. there was a remote thermostat which was set very high and therefore cut out very quickly. thanks for your help. rav
  8. R

    Heating suddenly stopped working.

    Hi I hope someone can help I have a heating issue,everything was workign fine, and suddenly stopped. i have hot water running, and works fine, but my rads are gettign no heat. I replaced the pump and fired up the boiler, then the boiler cuts out, and pump cuts out, and i get no...
  9. R

    british gas WR1 Wireless System to replace with hardwire

    hi thanks. i need to replace it as it regularly stops working and i have to switch the system off completely and then it kicks back in. i have changed the battery but it still does it. so i wanted to replace it with a hardwired as i have not had any issues with it. i have to check...
  10. R

    british gas WR1 Wireless System to replace with hardwire

    Hi I have a british gas WR1 Wireless System (drayton) wireless thermostat and i wanted to hardwire a new honeywell thermostat. Can anyone help me to do this please. thank you
  11. R

    POTTERTON 80, suddenly the heating system has stopped

    Hi I have a Potterton 80 boiler, system was working all fine with no probs, but i recently drained the rads, and now the system is all filled up, but suddenly the heaters are not warming up.. the boiler fires for 3 mins and then cuts off, the pipes are hot, but the first rad does not heat...
  12. R

    is it ok to bury pvc pipe under screed?

    i forgot to mention that the prob i have is that it is under a bath tile, what i had before was all pipe in screed, we upgraded the system and the pipe had a small crack in it and got larger due to pressure system. so now i have dug up the screed and tried to free the pipe as much as possible...
  13. R

    is it ok to bury pvc pipe under screed?

    thank you so it is ok to use barrier pipe, but to put membrane plastic over it, so the screed doesnt touch which also will give it room to expand? i will be onl needing to repair about 1.5 metre which have that is in screed. thank you
  14. R

    Bury Barrier pipe

    Hi i hope someone can help Is it ok to bury Barrier Pipe for hot & cold with elbows and couplers in screed? thanks in advance
  15. R

    is it ok to bury pvc pipe under screed?

    thanks for the reply. i had a leak under the bathroom tiles when the system was upgraded to megaflow. the copper pipe that was there had a crack for a long time, but due to high pressure system, it open and wasnt good. so i was thinking to use barrier pipe with a pvc coupler (grey...
  16. R

    is it ok to bury pvc pipe under screed?

    hi I hope you can help. i wanted to know if it is ok to bury barrier pipe in screed? i have a coupler that connects to copper and pvc pipe in the bathroom and need to bury it with screed, i can lag the pipe to protect it, but would it be a problem in the future?> thanks in advance
  17. R

    paxton access system - proffesional software key

    hi does anyone have the code for the paxton access system - proffesional software key? would be great if you do Thanks
  18. R

    Connecting a 230v to a relay for access system

    Hi I have a 230v smoke alarm, and i need to connect it to a access system so that if it goes off, the doors release. How do i wire or connect that/? thanks
  19. R

    how to change euro cylinder lock

    thanks for the reply so i need to get a small allen key 3mm or so to open it?
  20. R

    how to change euro cylinder lock

    Hi I have a aluminium door, that has a euro cylinder lock. i need to change it but cannot locate the screw on the inner side of the door. I can see when i push the handle up, the top and bottom bolts come out and i can see a hole where the cylinder screw suppose to be but isnt there. If i put...