  1. P

    Potterton Combi 80 Central Heating Issue

    1 of 2 problems, divertor, actually the wax casule in the divertor £125 with vat just for the part or the systems full of sludge, needs flush full day job 6-8 hours labour £500ish if done right with chemicals. to be honest this boiler is now at least 10 years old, and is on a...
  2. P

    Vaillant ecomax 824.. F23 fault code..

    Refers to circulation problem Check the rubber hose on the pipework these are prone to deteriorating and blocking internally
  3. P

    Vaillant Ecomax - Cuts out but no fault code?

    if it is having circulating problems its not usually the heat ex its normally the rubber hose
  4. P

    Condensing Combi Heatline 28 Boiler leaking - please help me

    these boilers a terrible heatlines usually leak from a black plastic nut inside the boiler, in a stuffing box on the pin in the divertor valve nightmare for parts tho cost is unbelievable, and you can't get service kits easy if it was mine it would be in a skip in 10mins...... sorry...
  5. P

    Baxi Solo 2PF

    valve works off ch switch on clock no need for a stat should be an easy swap for the clock, try a ACL/Drayton brand, back plate is nearly the same and may fit... if not it is easy to switch the back plates between the 2 now for the problem..... this could be a faulty motor in the 3 way...
  6. P

    Baxi 105e not going beyond 50deg

    i suppose you could access it yourself it only needs lifting up and the ch knob turning half a turn then refitting make sure the power is off alternativley get the guy back who fit pcb to fit it properly
  7. P

    Wireless Programmable stat query??

    it could possibly work, sunvic are v.poor go for drayton/acl but...... you can't just replace a stat with a wireless stat, you need a perminant electric supply to the reciever
  8. P

    Boiler Startup - Potterton Promax HE Plus

    combustion seals on this boiler are very poor, it may need the front combustion seal changing, especially if the condensate has backed up after freezing in recent weeks
  9. P

    Ideal Isar 24E issue!

    h3- definatly dhw thermistor l-f is flame detection..... this is usually caused by a blocked condensate, usually the trap in the boiler, they are a poor design, too small
  10. P

    Vokera Unica Syphon\trap question

    trap is always full to stop fumes escaping, emptys like any s trap
  11. P

    Help with Boiler!

    it could be as simple as the filling loop is letting water by, check this buy disconnecting it(silver braided hose, with a tap at each side) if it is passing it will constantly fill the system slowly.... if you disconnect it and it still continues to fill the plate heat exchanger is leaking...
  12. P

    glow worm 30sxi leaking - need help

    glowworm eng is right i'm afraid very poor installation, there should be a turret on the boiler with a correct seal and a flue sample point, this looks very dangerous!!
  13. P

    Baxi 105e not going beyond 50deg

    has the pcb been replaced recently????? if so it is a common fault to put the thermostat knob in upside down, therefore when you put it to maximum its only on about a 1/3 of its power, pcb needs re-fittin with the knob turned 180degrees
  14. P

    stabilised and thermostatically controlled?

    the difference between the too: thermostaticly controlled: constant temp, the shower mixes the right amount of cold and heat to provide the required temp stabilised: constant heat of the same power, probably high and low.... you regulate the temp with the flow rate of the water passing...