  1. spike47

    Seem to have a negative flow on underground soil pipe from Kitchen Drain

    Most of that run is only water etc from the kitchen, only the last 500mm, where the toilet flush enters the pipework
  2. spike47

    Seem to have a negative flow on underground soil pipe from Kitchen Drain

    Just to add, this pipework is under a concrete path
  3. spike47

    Seem to have a negative flow on underground soil pipe from Kitchen Drain

    Hi Have had a camera along the drain from inspection chamber to back of house drain that the roof and kitchen feed into and there seems to be a negative flow from about 3 meters from that drain that is only carrying water etc from kitchen, has per youtube vid attached, it is mainly due to some...
  4. spike47

    Renewing clay waste pipe

    Yeh, built 1964, yes, you are right , best to remove part of the path in question , which is around 6 Mtr and 3 Mtr round the corner , I did a cut into it awhile back with my Stihl saw and it cut down full cut of new blade , still solid concrete !. So I think I will do some cuts along the path...
  5. spike47

    Renewing clay waste pipe

    Hi My concrete path has been sinking along the side of my house, along with soil pipe underneath, for quite awhile and has dropped a full brick size now, have had a camera up it and water is pooling quite a bit from the end, so am going to replace part of the clay pipe with PVC, the concrete...
  6. spike47

    Garage Pit leaking water

    Hi Thanks for your reply, don't you think the method I suggested will not work ?. cheers
  7. spike47

    Garage Pit leaking water

    Hi Have a Pit in my garage, that is getting water in, mostly when it it rains heavy or rains for a long time, it is leaking through the breeze block sides , ( I did put some Visqueen around before bricking !) usually from about 2 bricks up from the floor, it will fill higher if left to. Wanted...
  8. spike47

    Problem with fitting a new FUHR Latch Gearbox

    Hi Thanks for that it does in a way, but mine is a Fuhr Gearbox, so not the same type of conecting it . cheers Spike
  9. spike47

    Problem with fitting a new FUHR Latch Gearbox

    Hi Have just fit a new Latch Gearbox for my Euro lock on my uPVC door, it all works ok , but the 2 point locking mechanism keeps sliding down with its own weight and bring out the locking points, it is just not staying up when opened, there is no resistance to hold it up , ! as per vid attached...
  10. spike47

    Seperating 2 lights with one switch to two switches

    The JB would of been accesable before the conversion, is it allowed to make them now unaccesable , just a thought .!
  11. spike47

    Seperating 2 lights with one switch to two switches

    Hi Have a lounge with 2 lights with one switch, need to make it one switch for each light, as there is a bit f a loft conversion, can't get at any junction boxes, wherever they may be that is, would it be accepted to try and run some cables along the ceiling ( cutting into it ), if I did that...
  12. spike47

    Pipes clanging when DHW calls or heat

    Pipes Clang ( don't know if it is the valve banging !) when the Boiler fires up first thing in a morning for HW !.
  13. spike47

    Pipes clanging when DHW calls or heat

    When the heating is shut down on a night and there is no power to the Actuator, the spring will pull the valve back to the HW position, that is the default setting ( HW prority ) !.
  14. spike47

    Pipes clanging when DHW calls or heat

    I don’t put the HW on, when the boiler fires up first thing in a morning the valve is already open for HW !
  15. spike47

    Pipes clanging when DHW calls or heat

    It happens ( The clanging ) first thing on a morning, when the boiler fires up for Hot water !
  16. spike47

    Pipes clanging when DHW calls or heat

    It seems the knocking is when the HW comes on, turned HW thermo down and CH started on the morning and no knocking !. Spike
  17. spike47

    Pipes clanging when DHW calls or heat

    Could I change over from DHW priority to CH priority, if so how can I do that ?. if the CH comes on first with the cylinder stat turned down, then after a hour, you turn the cylinder stat back up, there is less noise when the DHW kicks in ! Spike
  18. spike47

    Pipes clanging when DHW calls or heat

    Hi Thanks for your replies. 1: I don't think it will be from pipes expanding, it happens on a morning as soon has it fires up. 2: Pump is new ( 6 months old). 3: No gate valve on DHW Tank. 4: Yes, 22/15 Spike
  19. spike47

    Pipes clanging when DHW calls or heat

    Siemens DVA3. edit: Sorry not sure what make the valve is, just a plain 3 port valve , the Actuator is a Siemens mid way !. Spike
  20. spike47

    Pipes clanging when DHW calls or heat

    Hi Problem : Pipes clanging when DHW calls for heat Scenario, vented system CH system, clanging of pipes in a morning ( only morning ) when system starts up, have bled the system, set pump to II , no noise but downstairs rads not getting hot, pump back to III , turned DHW thermo down to "O"...