  1. L

    A mix of 10mm microbore and 15mm

    hi thanks for that, should i bother getting trvs for the 1st and 2nd floors then or shall i just use normal lockshield valves and just trvs on the 3rd floor, another idea i had was to put full bore isolating valves on the flow and return on the 1st floor just before the manifold and leave...
  2. L

    A mix of 10mm microbore and 15mm

    hi all, i have a town house (3 storrey) just getting ready to install my new combi boiler (vaillant). Im running from the boiler in 22mm to a manifold and from the manifold in 15mm, this is on the 2nd and 3rd floors, But here is the question the ground floor, has 22mm to a manifold then...
  3. L

    Before the possible Combi Arrives

    gas 4 u, i have chased the gaspipe back to the meter and i feel, if i need to get someone to run another pipe in it shouldnt be too much of a problem, i know where im going to install it now, and i feel with all the help you have given me it has taken a large weight off my shoulders, thank...
  4. L

    Before the possible Combi Arrives

    gas4u, when you say doubtfull, do you mean the gaspipes need to be a larger size, or the boiler needs to be closer the meter
  5. L

    Before the possible Combi Arrives

    with calculating the elbows, the boiler will be about 9 meters away from the gas metre and all pipe is 3/4" and i intend on installing a 37kw boiler, am i fine
  6. L

    Before the possible Combi Arrives

    i have measured the flowrate now from the kitchen tap, and that delivers a good 21 litres per minute so a lot greater than the 14.5 letres per minute i get on the 3rd floor ive also checked my gas pipes and they are 3/4"
  7. L

    Before the possible Combi Arrives

    i have measured the pressure and flow, so here goes i have static pressure of 4 bar, and a flow rate of 14.5 litres per min open pipe on the 3rd floor coming from a 15mm pipe. i have looked at the vaillant ecotec plus 37kw combi boiler for this house, any ideas
  8. L

    Before the possible Combi Arrives

    hi i managed to get a pressure tester, but no flow cup, i do know where to get one from so will pick that up next week, i only just put the mains tester on the garden tap so far which is a very short tee off the kitchen tap and the reading is 4.5bar, which surprises me, if that is the case...
  9. L

    Before the possible Combi Arrives

    going to get both a flow cup and a pressure tester, what sort of result (min) do i need from both pressure and flow thanks
  10. L

    Before the possible Combi Arrives

    gas As im in a town house i have no loft so the f+e tank is in the top of my built in wardrobe on the 3rd floor, im going to do it today, but what is the best way to measure, so i go out and get a measure or is there a better or madebe easier way,
  11. L

    Before the possible Combi Arrives

    thanks gas 4you, but from what source is best, shall i get it from the mains to my f+e tank, or shall i run a hosepipe up the side of the house from the mains and measure that way, or any other ideas accepted
  12. L

    Before the possible Combi Arrives

    hi so after Tony's response, i suppose i do need to worry about the pressure/flow. If im going to measure this properly how do you suggest i do this, i want to measure the flow and pressure on top floor as well as ground, any ideas
  13. L

    Before the possible Combi Arrives

    so do you think i need to worry about the pressure or flow of the mains coming to the house, if i go for a 37 or 40kw boiler, and just keep the shower electric, also am i forgetting any other important stuff thanks
  14. L

    Before the possible Combi Arrives

    i want to spend about 1K on the boiler and im going to do all the pipework myself, we mainly have showers, so am i still looking at the 37 or 40kw boiler. also is it worth me measuring the pressure of mains on the 3rd floor, i was going to measure this out of the mains to the current f+e tank
  15. L

    Before the possible Combi Arrives

    no thats the only shower, and the only bathroom, and kitchen is on ground floor, nothing but 3 rads on 2nd floor
  16. L

    Before the possible Combi Arrives

    good point, i must add i have the bathroom on the top floor along with 3 rads on each floor. Also i currently have an electric shower plumbed in is it worth keeping that or plumbing that into the combi also
  17. L

    Before the possible Combi Arrives

    hi all, I've had enough of the indirect system i have with a very old Glow worm boiler, so moving into the 21st century i think its time for a combi as its only myself and my partner in the house. BUT before i start doing anything to drastic, is there anything i really need to do or look into...
  18. L

    At my wits end, what am i doing wrong.

    sorry chris i tried it this weekend ive been fiddling around trying this and that since sat morning finished 8pm 2nite no luck tried all i put in previous to last thread and tried removing one but water came ****ing out thanx again
  19. L

    At my wits end, what am i doing wrong.

    tried what i said in last post does anyone know what i do now thanx
  20. L

    At my wits end, what am i doing wrong.

    so this is what im gonna try on sat, and i will let everyone know i suppose on sat nite or sun, here goes Turn the boiler on,turn all working rads OFF except the highest one, move all 2port valves open manually.then with the rads that dont work drain them until i get hot water then move on to...