    Baxi Fault

    Baxi 105HE fan or flue fault? Hi all, ok I have a Baxi 105he with a fan or flue fault light on, this started every few weeks and got worse until a full failer, i have changed the APS and this fixed the fault for all of two hour. i have checked for blocked Venturi,all APS pipes are fine. the...
  2. R

    Baxi 105HE flue/fan fault ??

    sorry ,APS was new from part center not ebay!! but good point about the pcb on ebay!!
  3. R

    Baxi 105HE flue/fan fault ??

    i see a few boilers use this pcb, a user has a new one on ebay , but it's from a different boiler (Potterton), could i use this pcb as they have the same part number regards rob
  4. R

    Baxi 105HE flue/fan fault ??

    hi, thanks for the reply, interesting about the pcb. looks like no option but to replace pcb, by the way the fan runs fine with no problems at all, before and after it fires up, strange how the new aps worked for a hour or so, at some points the heating can be running fine , and when it switches...
  5. R

    Baxi 105HE flue/fan fault ??

    Baxi 105HE fan or flue fault? Hi all, ok I have a Baxi 105he with a fan or flue fault light on, this started intermittently and got worse until a full failer, i have changed the APS and this fixed the fault for all of two hour. i have checked for blocked Venturi,all APS pipes are fine. the...
  6. R

    poor forum answers

    i was only making a point that the answers where very poor, with little follow up, guess i can not have a point of view . any way as this is my last post ,keep up the good work , and hope i don't have some of you to sort my boiler out,no wounder boiler repairs are so expensive , you don't know...
  7. R

    poor forum answers

    Sounds like nothing is going to change , maybe KEV should take over the running of the forum , he seems to have all the answers 'NOT, also like the sound of his own voice.
  8. R

    poor forum answers

    oops i didnt realise all post had to be serious sorry , i thought being without hw or ch was quite serious maybe not then?
  9. R

    poor forum answers

    ok 99% a little over the top , but reading the last 30 or so posts , the follow up is very poor , great to see a forum like this , but because a boiler cant be touch by mr diy , this does not mean that a question can not be answered, you don't need a ccn1 or acops to answer
  10. R

    poor forum answers

    how did i know you would reply, 99% of the p*iss takes are from you , read the last few of your post, very poor
  11. R

    poor forum answers

    after reading many posts ,i am seeing that 99% of all questions are not answered,and if they are they are very poor or are p*ss taking, i understand that most jobs should be left to the pro's,but if you are the customer with some knowledge this may save them time and money. :roll:
  12. R

    ariston combi,

    boiler serviced 4 months ago,any one else help?
  13. R

    ariston combi,

    when the boiler fires up ,im getting a big woosh and feels like boiler is going to take off, seems like there is a delay in igniting the burner and seems im getting a few seconds of gas build up, any idea? :roll:
  14. R

    ariston combi dhw noises when tap shut off

    hope you may be able to help, i have a ariston combi ,i guesss about two to three years old, heating has no problem at all and runs very nice ,apart from slight kettling, on dhw the system makes a very loud sound when the hot water tap is turned off( not water hammer), i also get the sound if...