    Zone valves for unvented cylinders

    I installed a Panasonic ashp with supplied diverter valve .Honeywell 2 port supplied with cylinder was repurposed for one of the heating circuits.As long as dhw fails closed on 3 port its cosher. Heatgeek & Urban plumber on yt explains indepth. I also queried this with the Panasonic rep.
  2. F

    RDB boiler not starting (video)

    Educated guess.In my area ill replace 20 oil pumps for every capacitor.Unfortunately service guys rarely clean oil filters in this neck of the woods which doesnt help.
  3. F

    RDB boiler not starting (video)

    oil pump about 80 quid with new drive.Best getting a boiler man to set it up and clean the oil filters including dipping for water content. £150 - £200 approximately.
  4. F

    Is this cylinder union failure really unfixable?

    If you dont fancy a goo ay sticky repair its possible to solder the back nut to the cylinder with traditional flux and flex and paste on thd threads that wont burn off. Fast and effective with all wters drained.
  5. F

    stirling locking out.

    25 year old myson shell 70/90 with stirling burner which is 10 years old. customer called me out as no heat.control stat was faulty so replaced and tested all fine. a week has now passed and it seems every 48hrs the boiler goes to l/out. oil sample clean. no wear at drive. pump pressure...
  6. F

    soot

    namsag i would agree with you.although before i start moving coals around i will run a temp gas supply direct from the bottles to the fire.this will confirm that the issue is at the fire and no where else.as stated before regulator etc all new. if it still soots up after ten minutes ill...
  7. F

    soot

    corgi- gasafe no need for silly questions jets cleaned by corgi/gassafe man he done more talking than work. checked up draught .2 out in his words which would have no ill effect on the fire. i am not at my parents so no idea of the model. fire is 5ish years old. thanks for your...
  8. F

    soot

    this is a complete gamble and could cost a lot of money to get a resault.thanks for your advise.
  9. F

    Oil Boiler Service - did he do it correctly?

    ahh,so at least theres a bit of hope in the PIPELINE. slapper if you come accross one of those devices with bells,whistles and gives a good B-----B ill have two of them! :D
  10. F

    30kW System Boiler Choice

    i thought i was stubborn...this might lighten the load. i knew a fella years ago that used calculate his rad size by the windows in the room.two 8"by4" windows in a living room would equal two 4"by 2" rads.no joke. he was the first person to teach me how to do a lead soldered wiped...
  11. F

    soot

    my father has coal effect gas fire.the fire is fed by bottled calor gas,8mm copper pipe.supply line about twenty feet.over the last year the pretend coals have started to soot up.all parts at the gas bottle end have been replaced,regulator etc. jets cleaned at fire place.coals arranged in...
  12. F

    warmflow oil boiler problems

    even though grundfos pumps are top of the range i would agree with boilerman2.faulty hot water prim pump not circulating and boiler going off on the high limit stat.thats were i would look first assuming pipework is correct. sounds like the burner needs set up/serviced also. i would be...
  13. F

    Oil Boiler Service - did he do it correctly?

    norcon i would say a lot of forgotten skill sets.i do not think i mentioned the words "four day course cowboys" as we all have to start somewhere.my replys were directed and about chestnut plumbings remarks and attitude etc...regarding the titanic i think there was more english,scottish and...
  14. F

    electro oil stirling 40 burner problem

    take a sample of oil from the oil pump flexi into a clear container so that you can inspect it.if you can not isolate the oil use vice grips to squeeze the flexi shut.extreme method but if you have no other choice etc.i would say the filter could be your problem.with a dodgy gatevalve it...
  15. F

    Oil Boiler Service - did he do it correctly?

    i came accross this thread by accident and it annoyed me that much i had to join up and reply.i never noticed the 2006 start date...yea 4 day oftec course ya gotta laugh.i had to do 5 years.welding,brazing,gas fitting,oil supply,dhw,pipe threading ,servicing hospital boilers you could sit and...
  16. F

    Oil Boiler Service - did he do it correctly?

    my father used this sort of kit.as for me slightly before my time.regarding the fga i was refering to the electronic devices. as for the procedure to set a twentyish year old boiler up without a fga i do not think it would be possible to explain.i think you need to be there in the...
  17. F

    Oil Boiler Service - did he do it correctly?

    what do you think was done 20 odd years ago when there was no fga ?????
  18. F

    Oil Boiler Service - did he do it correctly?

    i came accross this by accident....and i would guess you have probably been a painter and decorator since you left school and have now just completed an oftec course and its went to your head.its a big problem that joe blogs can be oftec registered in a very short period of time with no previous...