  1. A

    Texecom 48W ATS Path Fault on com2 - ComGSM

    Thanks for the help, I did power down ComGSM by removing the cover and power it up ----> working fine.
  2. A

    Texecom 48W ATS Path Fault on com2 - ComGSM

    I bought and installed the system Jan 2016. Premier Elite 48-W(v2.11) no idea of firmware on ComGSM I have not touched the ComGSM after installing, I willremove the cover and check it
  3. A

    Texecom 48W ATS Path Fault on com2 - ComGSM

    It is a pay as you go sim and I am able to send a text from keypad
  4. A

    Texecom 48W ATS Path Fault on com2 - ComGSM

    log.txt is attached, please have a look
  5. A

    Texecom 48W ATS Path Fault on com2 - ComGSM

    Hi, My system was working fine up to last Sunday Configuration Premier Elite 48-W(v2.11) COM1 - COMWiFi - only local access for wintex COM2 - ComGsm - vodafone SIM It is now reporting ats fault and it is coming back every time it is cleared RSSI = -55dBm I am able to send a text from...
  6. A

    SMS service centre number - ComGsm

    Hi, I am using ComGsm for SMS with Vodafone and the service numbers are 07785499993 and 07860 980480 Should not I use the Vodafone service numbers? 07785016005? Thanks
  7. A

    Impaq Contact-W is detecting tamper but always secure ?

    Thanks, I had reed disabled. fixed now
  8. A

    Impaq Contact-W is detecting tamper but always secure ?

    Hi Premier Elte 48-W system I have 3 Impaq Contact-W and I have installed 2 of them and working fine, I learnt the 3rd one and it seems to be fine but when I try to install I check the Zone status but this Zone is always secure never become active regardless of whether contact is kept close...
  9. A

    ComGSM ATS Path Fault and Com 2 Fault

    Yes, Thats right. I have another small question with reporting options I can understand some of them Priority - Panic Alarm Alarms - intruder Alarm Open and Close - ???? no idea (is it panel lid open/close?) Omits and Unomits - omitting Zones Maintenance Alarms - (from service interval in...
  10. A

    ComGSM ATS Path Fault and Com 2 Fault

    Hi Sparkymarka, Thanks for the quick response. The lid was closed, But I had the lid opened when I connect the ComGSM to control panel(and programmed) then only I closed the lid of ComGSM. I disconnected the ComGSM from panel and power downed, powered up, close the lid and programmed the...
  11. A

    ComGSM ATS Path Fault and Com 2 Fault

    Hi, I recently installed Premier Elite 48-W(v2.11) with ComGSM unit and trying to get it working. I have ComGSM in comport 2 and ComWiFi in comport 1 I am using ComWiFi for the local access of Wintex and want to use ComGSM for text messaging, I had ComGSM kind of working, was able to receive...
  12. A

    Baxi Solo WM 50/4 RS - need refilling?

    I think, it is a small cistern in the loft
  13. A

    Baxi Solo WM 50/4 RS - need refilling?

    Hi All, I want to change the motorised valve V4043H on a Baxi Solo WM 50/4 RS, but not able to find the filling loop or anything around boiler. could you please let me know how to drain down and refill it?