Search results

  1. C

    Hooks pulled out and damaged backboard

    Thank you for all the responses. For the batten - what screws can I use that are strong enough/heavy duty and long enough to go through the batten, back board and into the plaster board/bricked wall?
  2. C

    Hooks pulled out and damaged backboard

    Thank you for your response. Should have said the cupboard is sadly fitted into the wall so cannot be pulled out
  3. C

    Pressure keeps falling on the boiler?

    Two weeks back I noticed the boiler had an E0 error message. On checking further, the pressure had complete dropped into the red area. I re-pressurised the boiler to near the 2 mark and 2 weeks later the pressured is half way between 1 and 2. Is this because there may be a small leak in one of...
  4. C

    Hooks pulled out and damaged backboard

    My son accidentally pulled out the hooks within the coats cupboard by force when trying to get his coat out. The backboard is MDF and is around 2cm thick. Are there any ways of repairing this and getting the hooks in the same location or would we have to install the hooks in a new location now...
  5. C

    Hot water but no Central Heating with young children

    Thanks for all of your help. I managed to purchase a HONEYWELL 40003916-001 2-PORT V4043H REPLACEMENT POWERHEAD 22MM 22MM COMPRESSION from screwfix and watched a youtube video of how to change the motor from the old zone valve. Was very straight forward and although it was difficult getting a...
  6. C

    Hot water but no Central Heating with young children

    Thank you for all your responses. It turned out to be a faulty zone valve (far right). The two on the left (underfloor and cylinder) I put back to auto and far right zone valve I put on manual override. When getting the underfloor heating to come on or/and heating up the cylinder, the rads...
  7. C

    Hot water but no Central Heating with young children

    We have a Potterton Titanium Combi Gas Boiler which was setup with the wireless Nest Thermostat last year to provide heat to our radiators, heat up our unvented indirect cylinder to provide us hot water and to heat up our under floor heating in our kitchen. There is also one tap in the house...
  8. C

    Bike Shed Base Problems

    We bought a bike shed for our front garden and put it up today. The advise that was given prior to purchase was we need a level base for the bike shed otherwise we would have issues with it closing and locking it. I wasn't sure the shed based would be suitable however my wife was adamant that...
  9. C

    Indirect Unvented cylinder, Combi Boiler and Nest Thermostat

    So the gas light goes off (stops firing) however there rad light stays on and there is still some noise in the boiler for the duration of the scheduled time. I am not sure if it is setup up as hot water priority. How can I check? I also noticed that it takes 40seconds for any given tap in the...
  10. C

    Indirect Unvented cylinder, Combi Boiler and Nest Thermostat

    So tested it this morning. So the boiler comes on when it is heating up the cylinder (both gas light and rad light on boiler is lit) however it seems once it gets to the set temp, the gas light goes off but the rad light stays lit for the full duration of the set time. Is this normal/to be expected?
  11. C

    Indirect Unvented cylinder, Combi Boiler and Nest Thermostat

    Thanks for the response. The boiler is a Potterton Titanium 33kW. Have not tried it on a lower temp on the cylinder although will try it tomorrow and report back.
  12. C

    Indirect Unvented cylinder, Combi Boiler and Nest Thermostat

    We have just had an indirect unvented cylinder (250l Vertical Telford Tempest) installed along with a nest v3 thermostat. The plumber was able to modify our existing combi boiler, so it runs like a system boiler. I am trying to understand how it works as currently the plumber has set it to come...
  13. C

    Direct cylinder just to loft bathroom or Indirect Cylinder to whole house?

    We are having a loft conversion start in two weeks and are still struggling to find the best solution for getting a well pressured hot water supply to the loft when other bathrooms/ water outlets are in use. The loft bathroom will be used for occasionally for guests for now and in the future...
  14. C

    Wiring new doorbell and chime?

    All I can see is the following - Doorbell position - 2 * 2 core wires 1st Chime Position - 2 * 2 core wires 2nd Chime Position- 1 * 2 core wires I have just got myself a multimeter but it would be the first time I would be using it, so any advise on how I can check if any of the wires are...
  15. C

    Wiring new doorbell and chime?

    Was hoping to avoid that option as that would mean going into the walls again... Is there no way to go through a process of elimination or of some sort so can I can use the existing setup?
  16. C

    Wiring new doorbell and chime?

    Builders are no longer available to contact... I am just trying to figure out how to wire a new doorbell in preparation of the Ring pro.
  17. C

    Wiring new doorbell and chime?

    I don't but I remember the wires being live as when we moved in (builders carried out the work prior to moving in) I tried to connect a wired doorbell and chime. I remember it partially worked but the sound of the chime was not right and full on ..... if that makes sense....
  18. C

    Wiring new doorbell and chime?

    Any ideas guys how I will wire the bell and chime? Just to add - I have a 2nd chime unit in the kitchen area. I have just checked behind it and there are 2 wires located there as well.... So I assume the way it is setup is as follows - Kitchen Chimes to Doorbell? Doorway Chimes to Doorbell...
  19. C

    Wiring new doorbell and chime?

    Which black cable, there are a few? All done by the builders...
  20. C

    Wiring new doorbell and chime?

    So a little confused now... Here are the pics of behind the doorbell, where the chime will go and the consumer unit.... Not what I expected! I especially thought there would only be two wires behind the doorbell not 2 sets of 2...