  1. J

    Grundfos Mitsubishi Heat Pump recirculating pump

    I need some advise on a head replacement for a Grundfos pump fitted to a Mitsubishi Ecodan system. DHW circulation pump is stuck (tried unsticking but unsuccessful) and require a replacement. Replacement pump is £900+ which is ludicrous...
  2. J

    Texecom 64W Expander issue

    And indeed it does. Thank you kindly for your help
  3. J

    Texecom 64W Expander issue

    Quick check- will addressing the expander as 5 also cure the issue with the system seeing "tamper lost N1E1" as per the log file in picture 5?
  4. J

    Texecom 64W Expander issue

    Ahh brilliant thanks- wasn't sure what you meant by addressing the expander as 5 but makes sense now. Is there an option to map zones 41-48 to follow in numerical order? IE zone 1 through to 12 instead of 1-4 and then 41-48
  5. J

    Texecom 64W Expander issue

    Updated to share with public It will only be the one expander on the system as all the contacts/PIR's are hard wired and the main board only having 4 zones. (Sourced the 64W with Ricochet option reserved for future use) Been having the issue since installation and trying to commission, tried...
  6. J

    Texecom 64W Expander issue

    Good afternoon fellow DIY enthusiasts and professionals, I'm in need of some help with an issue I can't seem to fault find and get my head around. Network expander seemingly does not want to operate in N1E1 mode as per pictures- played around with the DIL switches till the cows came home and...
  7. J

    Enlarging bathroom window

    Hey there Stu- The professional look would be down to the bricky ;) I tried doing the brickwork myself but had to take it down as I wasn't happy with it- especially the outside brickwork. To be honest I didn't even bother with putting the lintel extension idea to Bco- doubt they would...
  8. J

    Sub floor preparation.

    Quick hello to all who reads & responds to the post. I'm after a bit of advice and guidance on a floor preparation prior to tiling. Bathroom will consist of a wetroom with underfloor heating. In order to keep the floor as low/original as possible I'm thinking of ripping up the old...
  9. J

    Enlarging bathroom window

    Was meaning to update the post with a picture of the lintel in place but didn't get to it. Lintel in place and bricked up- still waiting for the window to arrive before making an appointment with Bco to come & inspect it. Regards Jack
  10. Untitled

    Untitled

  11. J

    Enlarging bathroom window

    Hi there Stu- I'll fire an email to Ig in a minute or 2 and see what they come up with- but really can't see a load of 60Kn over 1.8m length To keep things simple I've decided to go with the cavity lintel-phoned Bco up to see if I can add the enlargement to an outstanding application and...
  12. J

    Enlarging bathroom window

    Had the acros delivered on Friday and thought i'd have a go at it the weekend- So far so good- just need to watch the weather now & catch a good day to get the outside done. Quick question on the steel lintel- i've emailed catnic with the details for selecting the lintel and they came back...
  13. Untitled

    Untitled

  14. Untitled

    Untitled

  15. Untitled

    Untitled

  16. J

    Enlarging bathroom window

    True indeed Stuart- that's the problem in the trade as well. It always makes sense up in the office on pc/drawings, but down on site it's a different story. And the somebody need to explain why the job took twice as long as what they "calculated" I'm hoping that the rebar would flex slightly...
  17. J

    Enlarging bathroom window

    Received a reply from hilti today: The intention is/was to drill 4 axial holes to a depth of 100mm into the faces of both lintels. I'm still not sure if this is the path i'd like to venture- but it helps knowing that this is an alternative. Regards Jack
  18. J

    Enlarging bathroom window

    Assuming it's a pre stressed lintel... It's another idea put out there- not saying that I'd be going down that route. I doubt you can call hilti hit a glue- I can assure you that on a pull test the concrete around the rods/bars will fail before the bars pull from the resin. Regards...
  19. J

    Enlarging bathroom window

    I'll email Hilti Uk with the above and see if they recommend joining concrete lintels with before sending off the application (with the email attached) Regards
  20. J

    Enlarging bathroom window

    Hi there Stuart- thanks once again for your reply. If we do decide to continue I'll have a chat to our local Bco and see if they need to issue a cert for the works carried out- already had him over to sign off the drainage that's been diverted and he seems like a nice enough chap. I've had...