    Remove air lock from storage tank on gravity feed open vent

    Hi Guys Had to drain my Potterton Open Vent, Gravity fed system via the lowest radiator so I could replace a pump by my boiler downstairs. Refilled and bled rads. Every radiator is nice and hot, however the two pipes that go in the side of my NEW copper hot water tank in Airiing cupboard are...
  2. M

    What is this and Can it be replaced? It's Leaking!

    Thanks. Then maybe I don't have a leak, maybe it's squeezing water out due to a problem with my Potterton Open Vent system??? I'll have another closer look.
  3. M

    Replacing SMC Pump Gasket - Can I Make a Gasket?

    Really appreciate advice. The pump is not working properly, so as a temporary fix I picked up an identical pump (but not a flange type) so wondered if I could undo those 4 hex bolts and swap over the pump part. I'm having a new system installed this Spring, so wanted temp fix to see me...
  4. M

    What is this and Can it be replaced? It's Leaking!

    Hi I have a leak by my old boiler (the 1st photo is a long shot so you get an idea of its position, the 2nd photo is a close up view.) Not sure what this does, but it looks like a cap put on end of pipe, but when I look close, there appears to be holes drilled around it???? This is where the...
  5. Untitled

    Untitled

  6. Untitled

    Untitled

  7. M

    Replacing SMC Pump Gasket - Can I Make a Gasket?

    Hi I'm about to take apart an old SMC Comet 2-120F Pump (see Picture), as this pump is no longer available I'm worried that once I disconnect it or take it apart, the gaskets will be ruined. As its old, I'm guessing I cannot go buy identical replacements???? Is it possible to make gaskets...
  8. Untitled

    Untitled

  9. Untitled

    Untitled

  10. M

    Advise about Old Potterton Central Heating Pump Removal!

    Would anyone recommend that I purchase a pump, but remove just the front housing, held on by 4 Hex bolt headsm I believe this holds all the electrics and the fan and motor part. Are the placement of those Hex bolts standard, so for example if I buy one of the Grundfos or Tuff pumps and unscrew...
  11. M

    Advise about Old Potterton Central Heating Pump Removal!

    thanks for the advise. I think I'll drain the system, would that be from a radiator downstairs? as I doubt the values will move. I will try and take the pump head off first and have a look, see if I can free up the pump, otherwise I'll hunt for a replacement pump... If all that fails a new...
  12. M

    Advise about Old Potterton Central Heating Pump Removal!

    Thanks. I think your right, the pump looks easier to remove by taking out the bolts you mention. As for the pump, WoW thats expensive, I didn't think SMC were still making these? Would I still need to drain all the water from the system before removing that front pump housing? Cheers
  13. M

    Advise about Old Potterton Central Heating Pump Removal!

    Hi Now before you laugh, yes I still have in my house the original Potterton Heating system from the 70's. As it has tanks in the loft, I assume its a gravity system. The problem is that radiators upstairs are perfect, but for the last week, the downstairs are cold. After reading these forums...
  14. Untitled

    Untitled

  15. Untitled

    Untitled

  16. Untitled

    Untitled

  17. Untitled

    Untitled

  18. Untitled

    Untitled

  19. Potterton Pump

    Potterton Pump

    Pictures from my Heating system
  20. M

    Water still in a Drained system???

    Sorry, its pump is by the boiler used to push water around the rads, Im guessing. The system does not have any modern fancy pumps whereby you can switch CH on only, or Water heating only. When you put the heating on, the water gets heated too. My system Water is in this pipe labelled B...